Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

LCP C130 JAPAN POLYPLASTIC
LAPEROS®
Electrical field,Electronic field,Household appliances,Household appliances
Flame retardant,High temperature resistan,Glass fiber reinforced,High mobility
ULMSDS
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
hardness | Test Condition | Test Method | JAPAN POLYPLASTIC/C130 |
---|---|---|---|
Rockwell hardness | M -Sale | ISO 2039-2 | 80 |
thermal performance | Test Condition | Test Method | JAPAN POLYPLASTIC/C130 |
---|---|---|---|
Hot deformation temperature | 8.0 MPa, Unannealed | ISO 75-2/C | 211 °C |
0.45 MPa, Unannealed | ISO 75-2/B | 250 °C | |
1.8 MPa, Unannealed | ISO 75-2/A | 255 °C | |
Linear coefficient of thermal expansion | Across Flow | ISO 11359-2 | 1.8E-5 cm/cm/°C |
Flow | ISO 11359-2 | 6.0E-6 cm/cm/°C | |
Melting temperature | ISO 11357-3 | 325 °C | |
Vicat softening temperature | ISO 306/B50 | 192 °C |
mechanical properties | Test Condition | Test Method | JAPAN POLYPLASTIC/C130 |
---|---|---|---|
Bending modulus | 23°C | ISO 178 | 14000 Mpa |
bending strength | 23°C | ISO 178 | 245 Mpa |
Compressive modulus | ISO 604 | 22000 Mpa | |
Compressive stress | 1% Strain | ISO 604 | 139 Mpa |
Tensile creep modulus | 1 hr | ISO 899-1 | 13600 Mpa |
1000 hr | ISO 899-1 | 11700 Mpa | |
Tensile modulus | ISO 527-2/1A | 15000 Mpa | |
Tensile strain | Break | ISO 527-2/1A/5 | 1.9 % |
tensile strength | Break | ISO 527-2/1A/5 | 160 Mpa |
Electrical performance | Test Condition | Test Method | JAPAN POLYPLASTIC/C130 |
---|---|---|---|
Arc resistance | Internal Method | 182 sec | |
Compared to the anti leakage trace index | IEC 60112 | PLC 3 | |
Dielectric strength | IEC 60243-1 | 35 KV/mm | |
Dissipation factor | 100 Hz | IEC 60250 | 0.014 |
1 MHz | IEC 60250 | 0.018 | |
Relative permittivity | 100 Hz | IEC 60250 | 4.20 |
1 MHz | IEC 60250 | 3.70 | |
Surface resistivity | IEC 60093 | > 1.0E+15 ohms | |
Volume resistivity | IEC 60093 | 1.0E+15 ohms·cm |
Physical properties | Test Condition | Test Method | JAPAN POLYPLASTIC/C130 |
---|---|---|---|
density | ISO 1183 | 1.62 g/cm³ | |
Shrinkage rate | 横向Flow | ISO 294-4 | 0.40 % |
Flow | ISO 294-4 | 0.20 % |
impact performance | Test Condition | Test Method | JAPAN POLYPLASTIC/C130 |
---|---|---|---|
Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 25 kJ/m² |
Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 20 kJ/m² |
Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 28 kJ/m² |
Suspended wall beam without notch impact strength | 23°C | ISO 180/1U | 26 kJ/m² |
flammability | Test Condition | Test Method | JAPAN POLYPLASTIC/C130 |
---|---|---|---|
Extreme Oxygen Index | ISO 4589-2 | 45 % | |
UL flame retardant rating | UL 94 | V-0 |
injection | Test Condition | Test Method | JAPAN POLYPLASTIC/C130 |
---|---|---|---|
Back pressure | < 3.00 Mpa | ||
drying temperature | 150 °C | ||
drying time | 4.0 to 6.0 hr | ||
Hopper temperature | 20 to 30 °C | ||
Injection speed | 快速 | ||
Mold temperature | 80 to 120 °C | ||
Processing (melt) temperature | 320 to 340 °C | ||
Spray nozzle temperature | 310 to 330 °C | ||
Suggested maximum moisture content | 0.010 % | ||
Temperature at the front of the material cylinder | 310 to 320 °C | ||
Temperature at the rear of the barrel | 290 to 300 °C | ||
Temperature in the middle of the barrel | 300 to 310 °C |