Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA66 AS-V0 NC EMS-CHEMIE SWITZERLAND
Grilon®
Industrial machinery,Household daily necessities
High hardness,High temperature resistan
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
thermal performance | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/AS-V0 NC |
---|---|---|---|
Continuous use temperature | --3 | ISO 2578 | 90.0 to 110 °C |
--4 | Internal Method | 200 °C | |
Hot deformation temperature | 0.45 MPa, Unannealed | ISO 75-2/B | 225 °C |
1.8 MPa, Unannealed | ISO 75-2/A | 75.0 °C | |
Linear coefficient of thermal expansion | Across Flow | ISO 11359-2 | 9.0E-5 cm/cm/°C |
Flow | ISO 11359-2 | 6.0E-5 cm/cm/°C | |
Melting temperature | ISO 11357-3 | 260 °C |
mechanical properties | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/AS-V0 NC |
---|---|---|---|
Nominal tensile fracture strain | ISO 527-2 | 9.0 % | |
Tensile modulus | ISO 527-2 | 3900 Mpa | |
Tensile strain | Yield | ISO 527-2 | 4.0 % |
tensile strength | Yield | ISO 527-2 | 90.0 Mpa |
Break | ISO 527-2 | 80.0 Mpa |
Electrical performance | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/AS-V0 NC |
---|---|---|---|
Compared to the anti leakage trace index | IEC 60112 | V | |
Dielectric strength | IEC 60243-1 | 31 KV/mm | |
Dissipation factor | 100 Hz | IEC 60250 | 3.0E-3 |
1 MHz | IEC 60250 | 0.020 | |
Relative permittivity | 100 Hz | IEC 60250 | 3.00 |
1 MHz | IEC 60250 | 4.00 | |
Surface resistivity | IEC 60093 | -- ohms | |
Volume resistivity | IEC 60093 | 1.0E+14 ohms·cm |
Physical properties | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/AS-V0 NC |
---|---|---|---|
Shrinkage rate | 横向Flow | ISO 294-4 | 1.1 % |
Flow | ISO 294-4 | 0.90 % | |
Water absorption rate | Saturation, 23°C | ISO 62 | 7.0 % |
Equilibrium, 23°C, 50% RH | ISO 62 | 2.0 % |
impact performance | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/AS-V0 NC |
---|---|---|---|
Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 65 kJ/m² |
flammability | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/AS-V0 NC |
---|---|---|---|
Extreme Oxygen Index | ISO 4589-2 | 32 % | |
Flammability level | UL 94 | V-0 | |
ISO Type | ISO 1874 | PA 66. MFHR. 14-040 |