Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PSU Thermalux® Unfilled Westlake Plastics Company
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | Westlake Plastics Company/Thermalux® Unfilled |
---|---|---|---|
Impact strength of cantilever beam gap | 23°C | ASTM D256 | 69 J/m |
Suspended wall beam without notch impact strength | ASTM D256 | 无断裂 |
hardness | Test Condition | Test Method | Westlake Plastics Company/Thermalux® Unfilled |
---|---|---|---|
Rockwell hardness | R级 | ASTM D785 | 120 |
M级 | ASTM D2240 | 69 |
Mechanical properties | Test Condition | Test Method | Westlake Plastics Company/Thermalux® Unfilled |
---|---|---|---|
elongation | 断裂 | ASTM D638 | 50to100 % |
屈服 | ASTM D638 | 5.0-6.0 % | |
bending strength | 屈服 | ASTM D790 | 106 MPa |
compressive strength | ASTM D695 | 95.8 MPa | |
Flexural modulus | ASTM D790 | 2690 MPa | |
Tensile modulus | ASTM D638 | 2480 MPa | |
tensile strength | 屈服 | ASTM D638 | 70.3 MPa |
Electrical performance | Test Condition | Test Method | Westlake Plastics Company/Thermalux® Unfilled |
---|---|---|---|
Dissipation Factor | 1kHz | ASTM D150 | 1E-03 |
Volume resistivity | ASTM D257 | 5E+16 ohms·cm | |
dielectric strength | ASTM D149 | 17 kV/mm | |
dielectric constant | 1kHz | ASTM D150 | 3.06 |
optical performance | Test Condition | Test Method | Westlake Plastics Company/Thermalux® Unfilled |
---|---|---|---|
transmissivity | ASTM D1746 | 75.0 % | |
Haze ratio | ASTM D1746 | 5.0 % |
flammability | Test Condition | Test Method | Westlake Plastics Company/Thermalux® Unfilled |
---|---|---|---|
UL flame retardant rating | 4.5mm | UL 94 | V-0 |
Limiting Oxygen Index | ASTM D2863 | 30 % |
physical property | Test Condition | Test Method | Westlake Plastics Company/Thermalux® Unfilled |
---|---|---|---|
Water absorption rate | 24hr | ASTM D570 | 0.30 % |
density | ASTM D792 | 1.24 g/cm³ |
Thermal performance | Test Condition | Test Method | Westlake Plastics Company/Thermalux® Unfilled |
---|---|---|---|
Heat distortion temperature | 1.8MPa,未退火,HDT | ASTM D648 | 174 °C |
0.45MPa,未退火,HDT | ASTM D648 | 181 °C | |
thermal conductivity | ASTMC177 | 0.26 W/m/K | |
Linear coefficient of thermal expansion | MD | ASTM D696 | 5.6E-05 cm/cm/°C |
Contact Us
Get App
Top