Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA12 VESTAMID® L L2122 Altuglas International of Arkema Inc.
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | Altuglas International of Arkema Inc./VESTAMID® L L2122 |
---|---|---|---|
Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | NoBreak |
23°C | ISO 179/1eU | NoBreak | |
Charpy Notched Impact Strength | 23°C,局部断裂 | ISO 179/1eA | 68 kJ/m² |
-30°C,完全断裂 | ISO 179/1eA | 6.0 kJ/m² |
Supplementary Information | Test Condition | Test Method | Altuglas International of Arkema Inc./VESTAMID® L L2122 |
---|---|---|---|
electrolytic corrosion | IEC 60426 | A1 | |
ISO Shortcut | ISO 1874 | PA12-P.EHL.22-005 |
Electrical performance | Test Condition | Test Method | Altuglas International of Arkema Inc./VESTAMID® L L2122 |
---|---|---|---|
Compared to the Leakage Tracking Index (CTI) | SolutionA3 | IEC 60112 | PLC 0 |
dielectric strength | IEC 60243-1 | 32 kV/mm | |
Volume resistivity | IEC 60093 | 1E+13 ohms·cm | |
relative permittivity | 23°C,1MHz | IEC 60250 | 3.30 |
23°C,100Hz | IEC 60250 | 10.0 | |
Dissipation Factor | 23°C,100Hz | IEC 60250 | 0.19 |
23°C,1MHz | IEC 60250 | 0.10 | |
Compared to the Leakage Tracking Index (CTI) | -- | IEC 60112 | PLC 0 |
Mechanical properties | Test Condition | Test Method | Altuglas International of Arkema Inc./VESTAMID® L L2122 |
---|---|---|---|
Tensile modulus | ISO 527-2 | 490 MPa | |
Tensile strain | 断裂 | ISO 527-2 | >50 % |
屈服 | ISO 527-2 | 26 % | |
tensile strength | 屈服 | ISO 527-2 | 30.0 MPa |
flammability | Test Condition | Test Method | Altuglas International of Arkema Inc./VESTAMID® L L2122 |
---|---|---|---|
UL flame retardant rating | 3.2mm | UL 94 | HB |
1.6mm | UL 94 | HB |
physical property | Test Condition | Test Method | Altuglas International of Arkema Inc./VESTAMID® L L2122 |
---|---|---|---|
density | 23°C | ISO 1183 | 1.03 g/cm³ |
Shrinkage rate | TD | ISO 294-4 | 1.6 % |
MD | ISO 294-4 | 0.60 % | |
Water absorption rate | 平衡,23°C,50%RH | ISO 62 | 0.50 % |
Thermal performance | Test Condition | Test Method | Altuglas International of Arkema Inc./VESTAMID® L L2122 |
---|---|---|---|
melting temperature | ISO 11357-3 | 173 °C | |
Linear coefficient of thermal expansion | MD:23到55°C | ISO 11359-2 | 1.7E-04 cm/cm/°C |
Heat distortion temperature | 0.45MPa,未退火,HDT | ISO 75-2/B | 95.0 °C |
1.8MPa,未退火,HDT | ISO 75-2/A | 45.0 °C | |
vicat | -- | ISO 306/B | 125 °C |
-- | ISO 306/A | 165 °C |