Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

Polyolefin, Unspecified Lucofin® 7410 HFFR LUCOBIT GERMANY
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| hardness | Test Condition | Test Method | LUCOBIT GERMANY/Lucofin® 7410 HFFR |
|---|---|---|---|
| Shore hardness | ShoreD | ISO 868 | 52 |
| thermal performance | Test Condition | Test Method | LUCOBIT GERMANY/Lucofin® 7410 HFFR |
|---|---|---|---|
| ColdElongation | IEC 60811-1-4 | 140 % | |
| Hot pressing test | 90°C | IEC 60811-3-1 | 5.0 % |
| mechanical properties | Test Condition | Test Method | LUCOBIT GERMANY/Lucofin® 7410 HFFR |
|---|---|---|---|
| Tensile strain | Break | IEC 60811-1-1 | 180 % |
| Break,110°C3 | IEC 60811-1-1 | 160 % | |
| Break伸长率-variationfromoriginal4(70°C) | IEC 60811-1-1 | -6.0 % | |
| 抗张强度-variationfromoriginal4(70°C) | IEC 60811-1-1 | -17 % | |
| tensile strength | -- | IEC 60811-1-1 | 11.0 MPa |
| 110°C3 | IEC 60811-1-1 | 10.7 MPa |
| Electrical performance | Test Condition | Test Method | LUCOBIT GERMANY/Lucofin® 7410 HFFR |
|---|---|---|---|
| Dielectric constant | 50Hz6 | IEC 60250 | 3.70 |
| 20°C,50Hz9 | IEC 60250 | 6.10 | |
| Dissipation factor | 传导率 | IEC 60250 | 2.80 µS/cm |
| 50Hz6 | IEC 60250 | 0.026 | |
| 20°C,50Hz9 | IEC 60250 | 0.13 | |
| Surface resistivity | --6 | IEC 60093 | 3.7E+14 ohms |
| --7 | IEC 60093 | 4.8E+14 ohms | |
| Volume resistivity | --6 | IEC 60093 | 1.1E+15 ohms·cm |
| 70°C8 | IEC 60093 | 3.6E+14 ohms·cm |
| Physical properties | Test Condition | Test Method | LUCOBIT GERMANY/Lucofin® 7410 HFFR |
|---|---|---|---|
| density | ISO 1183 | 1.48 g/cm³ | |
| melt mass-flow rate | 150°C/21.6kg | ISO 1133 | 6.0 g/10min |
| Mooney viscosity | ML1+4,140°C | ASTM D792 | 39 MU |
| PH value | 5.9 | ||
| Water absorption rate | 70°C | IEC 60811-1-3 | 0.500 mg/cm² |
| flammability | Test Condition | Test Method | LUCOBIT GERMANY/Lucofin® 7410 HFFR |
|---|---|---|---|
| Extreme Oxygen Index | ISO 4589-2 | 36 % | |
| HalogenContent | IEC 754-1 | <5 mg/g | |
| toxicity | EN50305 | 2.30 |
| aging | Test Condition | Test Method | LUCOBIT GERMANY/Lucofin® 7410 HFFR |
|---|---|---|---|
| Change rate of tensile strength in air | BS6724 | 94 % | |
| Elongation retention rate | Break时 | BS6724 | 97 % |