plas

Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PPO GFN3-701 SABIC INNOVATIVE THAILAND
NORYL™ 
Lawn equipment,Garden equipment,Non specific food,Outdoor applications,Electrical field,Electronic field,Architectural application field,Liquid handling,Electrical appliances,Engine hood parts,Medical supplies,Nursing supplies,Plastic bag,Automotive External Parts,Lighting applications
enhance,Glass fiber reinforced,Hydrolysis resistance
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

hardnessTest ConditionTest MethodSABIC INNOVATIVE THAILAND/GFN3-701
Rockwell hardnessL计秤ASTM D785108
thermal performanceTest ConditionTest MethodSABIC INNOVATIVE THAILAND/GFN3-701
Hot deformation temperature1.8MPa,Unannealed,64.0mmSpanISO 75-2/Af137 °C
0.45MPa,未退火,3.20mmASTM D648142 °C
0.45MPa,未退火,6.40mmASTM D648158 °C
1.8MPa,未退火,6.40mmASTM D648138 °C
0.45MPa,Unannealed,64.0mmSpanISO 75-2/Bf143 °C
1.8MPa,未退火,3.20mmASTM D648137 °C
Linear coefficient of thermal expansionTD:-40到40°CASTME8316.2E-05 cm/cm/°C
MD:-40到40°CASTME8313.1E-05 cm/cm/°C
RTI ElecUL 74690.0 °C
RTI ImpUL 74690.0 °C
RTI StrUL 74690.0 °C
Vicat softening temperature--ISO 306/B120147 °C
--ISO 306/B50143 °C
mechanical propertiesTest ConditionTest MethodSABIC INNOVATIVE THAILAND/GFN3-701
Bending modulus50.0mm跨距5ASTM D7908000 Mpa
ISO 1788710 Mpa
100mmSpan4ASTM D7907170 Mpa
bending strengthISO 178183 Mpa
Yield,100mmSpan4ASTM D790162 Mpa
屈服,50.0mm跨距5ASTM D790180 Mpa
elongation断裂ASTM D6382.0 %
Tensile modulusISO 527-2/18740 Mpa
ASTM D6389150 Mpa
Tensile strain断裂ISO 527-21.8 %
tensile strength断裂ASTM D638116 Mpa
断裂ISO 527-2117 Mpa
Electrical performanceTest ConditionTest MethodSABIC INNOVATIVE THAILAND/GFN3-701
Arc resistanceASTM D495PLC7
Compared to the anti leakage trace indexCTIUL 746PLC 4
Dielectric constant50HzASTM D1502.93
60HzASTM D1502.93
Dielectric strength3.20mm,inOilASTM D14922 KV/mm
Dissipation factor60HzASTM D1509E-04
50HzASTM D1509E-04
High arc combustion indexHAIUL 746PLC 4
High voltage arc tracing rateHVTRUL 746PLC 3
Hot wire ignitionHWIUL 746PLC 4
Physical propertiesTest ConditionTest MethodSABIC INNOVATIVE THAILAND/GFN3-701
melt mass-flow rate300°C/5.0kgASTM D12388.7 g/10min
Melt Volume Flow Rate (MVR)300°C/5.0kgISO 11337.82 cm3/10min
Shrinkage rateMD:3.20mmInternal Method0.10-0.40 %
Water absorption rate24hrASTM D5700.060 %
impact performanceTest ConditionTest MethodSABIC INNOVATIVE THAILAND/GFN3-701
Impact strength of cantilever beam gap-30°CISO 180/1A12 kJ/m²
23°CISO 180/1A12 kJ/m²
Impact strength of simply supported beam without notch-30°CISO 179/1eU47 kJ/m²
23°CISO 179/1eU39 kJ/m²
Suspended wall beam without notch impact strength23°CISO 180/1U32 kJ/m²
-30°CISO 180/1U36 kJ/m²
flammabilityTest ConditionTest MethodSABIC INNOVATIVE THAILAND/GFN3-701
Extreme Oxygen IndexASTM D286326 %
UL flame retardant rating1.5mmUL 94HB