Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PPO GFN3-701 SABIC INNOVATIVE THAILAND
NORYL™
Lawn equipment,Garden equipment,Non specific food,Outdoor applications,Electrical field,Electronic field,Architectural application field,Liquid handling,Electrical appliances,Engine hood parts,Medical supplies,Nursing supplies,Plastic bag,Automotive External Parts,Lighting applications
enhance,Glass fiber reinforced,Hydrolysis resistance
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| hardness | Test Condition | Test Method | SABIC INNOVATIVE THAILAND/GFN3-701 |
|---|---|---|---|
| Rockwell hardness | L-Sale | ASTM D785 | 108 |
| thermal performance | Test Condition | Test Method | SABIC INNOVATIVE THAILAND/GFN3-701 |
|---|---|---|---|
| Hot deformation temperature | 1.8MPa,Unannealed,3.20mm | ASTM D648 | 137 °C |
| 1.8MPa,Unannealed,6.40mm | ASTM D648 | 138 °C | |
| 1.8MPa,Unannealed,64.0mmSpan | ISO 75-2/Af | 137 °C | |
| 0.45MPa,Unannealed,3.20mm | ASTM D648 | 142 °C | |
| 0.45MPa,Unannealed,6.40mm | ASTM D648 | 158 °C | |
| 0.45MPa,Unannealed,64.0mmSpan | ISO 75-2/Bf | 143 °C | |
| Linear coefficient of thermal expansion | MD:-40to40°C | ASTME831 | 3.1E-05 cm/cm/°C |
| TD:-40to40°C | ASTME831 | 6.2E-05 cm/cm/°C | |
| RTI Elec | UL 746 | 90.0 °C | |
| RTI Imp | UL 746 | 90.0 °C | |
| RTI Str | UL 746 | 90.0 °C | |
| Vicat softening temperature | -- | ISO 306/B120 | 147 °C |
| -- | ISO 306/B50 | 143 °C |
| mechanical properties | Test Condition | Test Method | SABIC INNOVATIVE THAILAND/GFN3-701 |
|---|---|---|---|
| Bending modulus | 50.0mmSpan5 | ASTM D790 | 8000 Mpa |
| ISO 178 | 8710 Mpa | ||
| 100mmSpan4 | ASTM D790 | 7170 Mpa | |
| bending strength | Yield,50.0mmSpan5 | ASTM D790 | 180 Mpa |
| ISO 178 | 183 Mpa | ||
| Yield,100mmSpan4 | ASTM D790 | 162 Mpa | |
| elongation | Break | ASTM D638 | 2.0 % |
| Tensile modulus | ISO 527-2/1 | 8740 Mpa | |
| ASTM D638 | 9150 Mpa | ||
| Tensile strain | Break | ISO 527-2 | 1.8 % |
| tensile strength | Break | ASTM D638 | 116 Mpa |
| Break | ISO 527-2 | 117 Mpa |
| Electrical performance | Test Condition | Test Method | SABIC INNOVATIVE THAILAND/GFN3-701 |
|---|---|---|---|
| Arc resistance | ASTM D495 | PLC7 | |
| Compared to the anti leakage trace index | CTI | UL 746 | PLC 4 |
| Dielectric constant | 50Hz | ASTM D150 | 2.93 |
| 60Hz | ASTM D150 | 2.93 | |
| Dielectric strength | 3.20mm,inOil | ASTM D149 | 22 KV/mm |
| Dissipation factor | 60Hz | ASTM D150 | 9E-04 |
| 50Hz | ASTM D150 | 9E-04 | |
| High arc combustion index | HAI | UL 746 | PLC 4 |
| High voltage arc tracing rate | HVTR | UL 746 | PLC 3 |
| Hot wire ignition | HWI | UL 746 | PLC 4 |
| Physical properties | Test Condition | Test Method | SABIC INNOVATIVE THAILAND/GFN3-701 |
|---|---|---|---|
| melt mass-flow rate | 300°C/5.0kg | ASTM D1238 | 8.7 g/10min |
| Melt Volume Flow Rate (MVR) | 300°C/5.0kg | ISO 1133 | 7.82 cm3/10min |
| Shrinkage rate | MD:3.20mm | Internal Method | 0.10-0.40 % |
| Water absorption rate | 24hr | ASTM D570 | 0.060 % |
| impact performance | Test Condition | Test Method | SABIC INNOVATIVE THAILAND/GFN3-701 |
|---|---|---|---|
| Impact strength of cantilever beam gap | -30°C | ISO 180/1A | 12 kJ/m² |
| 23°C | ISO 180/1A | 12 kJ/m² | |
| Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 47 kJ/m² |
| 23°C | ISO 179/1eU | 39 kJ/m² | |
| Suspended wall beam without notch impact strength | 23°C | ISO 180/1U | 32 kJ/m² |
| -30°C | ISO 180/1U | 36 kJ/m² |
| flammability | Test Condition | Test Method | SABIC INNOVATIVE THAILAND/GFN3-701 |
|---|---|---|---|
| Extreme Oxygen Index | ASTM D2863 | 26 % | |
| UL flame retardant rating | 1.5mm | UL 94 | HB |