PC 945A-116 SABIC INNOVATIVE NANSHA
LEXAN™ 
Plastic bag,Lawn equipment,Garden equipment,Outdoor applications,Architectural application field,medicine,Electrical field,Electronic field,Engine hood parts,Liquid handling,Electrical appliances,Automotive External Parts,Lighting applications
Flame retardant,Bromine free,currency
UL
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

hardnessTest ConditionTest MethodSABIC INNOVATIVE NANSHA/945A-116
Ball Pressure TestH358/30ISO 2039-195.0 Mpa
thermal performanceTest ConditionTest MethodSABIC INNOVATIVE NANSHA/945A-116
0.45MPa, unannealed, 100mm spanISO 75-2/Be136 °C
1.8MPa, unannealed, 100mm spanISO 75-2/Ae125 °C
Ball Pressure Test125°CIEC 60695-10-2Pass
Linear coefficient of thermal expansionMD:23to80°CISO 11359-27E-05 cm/cm/°C
TD:23to80°CISO 11359-27E-05 cm/cm/°C
RTIUL 746125 °C
RTI ElecUL 746130 °C
RTI ImpUL 746120 °C
thermal conductivityISO 83020.20 W/m/K
mechanical propertiesTest ConditionTest MethodSABIC INNOVATIVE NANSHA/945A-116
Bending modulusISO 1782300 Mpa
bending strengthISO 17890.0 Mpa
Tensile modulusISO 527-2/12350 Mpa
Tensile strainBreakISO 527-2/50100 %
YieldISO 527-2/506.0 %
tensile strengthYieldISO 527-2/5063.0 Mpa
BreakISO 527-2/5065.0 Mpa
Electrical performanceTest ConditionTest MethodSABIC INNOVATIVE NANSHA/945A-116
Compared to the anti leakage trace indexIEC 60112PLC 3
Dielectric strength3.20mm,in OilIEC 60243-117 KV/mm
Dissipation factor1MHzIEC 602500.010
50HzIEC 602501E-03
60HzIEC 602501E-03
Relative permittivity60HzIEC 602502.70
50HzIEC 602502.70
1MHzIEC 602502.70
Surface resistivityIEC 60093>1.0E+15 ohms
Volume resistivityIEC 60093>1.0E+15 ohms·cm
Physical propertiesTest ConditionTest MethodSABIC INNOVATIVE NANSHA/945A-116
Melt Volume Flow Rate (MVR)300°C/1.2kgISO 113310.0 cm3/10min
Outdoor applicabilityUL 746Cf1
Shrinkage rateMD1Internal Method0.50-0.70 %
Water absorption rateEquilibrium,23°C,50%RHISO 620.15 %
Saturation,23°CISO 620.35 %
impact performanceTest ConditionTest MethodSABIC INNOVATIVE NANSHA/945A-116
Charpy Notched Impact Strength23°CISO 179/1eA73 kJ/m²
-30°CISO 179/1eA14 kJ/m²
Impact strength of cantilever beam gap-30°CISO 180/1A12 kJ/m²
23°CISO 180/1A70 kJ/m²
Impact strength of simply supported beam without notch-30°CISO 179/1eU无断裂
23°CISO 179/1eU无断裂
Suspended wall beam without notch impact strength-30°CISO 180/1U无断裂
23°CISO 180/1U无断裂
flammabilityTest ConditionTest MethodSABIC INNOVATIVE NANSHA/945A-116
Burning wire flammability index1.00mmIEC 60695-2-12960 °C
Extreme Oxygen IndexISO 4589-235 %
Hot filament ignition temperature1.00mmIEC 60695-2-13850 °C
UL flame retardant rating3.00mmUL 94V-0
1.50mmUL 94V-2
optical performanceTest ConditionTest MethodSABIC INNOVATIVE NANSHA/945A-116
Refractive indexISO 4891.586
transmissivity2540μmASTM D100388.0 %