Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PBT SK601 NC010 DUPONT USA
Cristin®
Electronic and electrical components,Automotive Applications
Glass fiber reinforced
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
thermal performance | Test Condition | Test Method | DUPONT USA/SK601 NC010 |
---|---|---|---|
Heat Deflection Temperature | 0.45MPa未退火,HDT | ISO 75-2/Bf | 215 °C |
1.80MPa未退火,HDT | ISO 75-2/Af | 175 °C | |
vicat | ISO 306/B50 | 205 °C | |
Linear coefficient of thermal expansion | TD | ISO 11359-2 | 1.2E-04 cm/cm/°C |
melting temperature | ISO 11357-3 | 225 °C | |
Linear coefficient of thermal expansion | MD | ISO 11359-2 | 6E-05 cm/cm/°C |
Electrical performance | Test Condition | Test Method | DUPONT USA/SK601 NC010 |
---|---|---|---|
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 2 | |
dielectric strength | IEC 60243-1 | 35 KV/mm | |
volume resistivity | IEC 60093 | 1E+16 Ω.cm | |
dielectric constant | 23°C | IEC 60250 | 3.50 1MHz |
Dissipation Factor | 23°C | IEC 60250 | 0.020 1MHz |
dielectric constant | 23°C | IEC 60250 | 3.90 100HZ |
Dissipation Factor | 23°C | IEC 60250 | 2E-03 100HZ |
Mechanical properties | Test Condition | Test Method | DUPONT USA/SK601 NC010 |
---|---|---|---|
tensile strength | 23°C | ISO 527-2 | 90 Mpa |
Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 6.00 kJ/m² |
Suspended wall beam without notch impact strength | -30°C | ISO 180/1U | 26 kJ/m² |
Tensile creep modulus | 1000Hr | ISO 899-1 | 2500 Mpa |
Tensile modulus | 23°C | ISO 527-2 | 4500 Mpa |
Suspended wall beam without notch impact strength | 23°C | ISO 180/1U | 27 kJ/m² |
Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 40 kJ/m² |
Impact strength of cantilever beam gap | -30°C | ISO 180/1A | 5.00 kJ/m² |
Tensile creep modulus | 1Hr | ISO 899-1 | 4000 Mpa |
Elongation at break | 23°C | ISO 527-2 | 4.70 % |
bending strength | 23°C | ISO 178 | 140 Mpa |
Charpy Notched Impact Strength | -30°C | ISO 179/1eA | 6.00 kJ/m² |
Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 4.50 kJ/m² |
Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 40 kJ/m² |
Physical properties | Test Condition | Test Method | DUPONT USA/SK601 NC010 |
---|---|---|---|
Water absorption rate | 23°C,50RH | ISO 62 | 0.20 % |
shrinkage rate | MD2.0mm | ISO 294-4 | 0.70 % |
Water absorption rate | 23°C,24hr | ISO 62 | 0.40 % |
shrinkage rate | TD2.0mm | ISO 294-4 | 1.20 % |
flammability | Test Condition | Test Method | DUPONT USA/SK601 NC010 |
---|---|---|---|
UL flame retardant rating | Allcolor | UL -94 | HB 6.00mm |
Allcolor | UL -94 | HB 1.50mm | |
Allcolor | UL -94 | HB 3.00mm | |
Allcolor | UL -94 | 0.75mm | |
Limiting Oxygen Index | ISO 4589-2 | 20 % |
Contact Us
Get App
Top