Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA6 B3 GF 15 1 L BK AKRO-PLASTIC GERMANY
AKROMID®
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | AKRO-PLASTIC GERMANY/B3 GF 15 1 L BK |
---|---|---|---|
Impact strength of simply supported beam without notch | 23°C | ISO179/1eU | 60 kJ/m² |
-30°C | ISO179/1eU | 60 kJ/m² |
Supplementary Information | Test Condition | Test Method | AKRO-PLASTIC GERMANY/B3 GF 15 1 L BK |
---|---|---|---|
ReinforcementContent | ISO1172 | 15 % |
Mechanical properties | Test Condition | Test Method | AKRO-PLASTIC GERMANY/B3 GF 15 1 L BK |
---|---|---|---|
Tensile stress | 断裂 | ISO527-2/5 | 105 Mpa |
Tensile modulus | ISO527-2/1 | 5200 Mpa | |
Tensile strain | 断裂 | ISO527-2/5 | 3.3 % |
flammability | Test Condition | Test Method | AKRO-PLASTIC GERMANY/B3 GF 15 1 L BK |
---|---|---|---|
Burning rate 5 | 1.00mm | FMVSS302 | <100 mm/min |
Burning wire flammability index | 0.8mm | IEC60695-2-12 | 700 °C |
UL flame retardant rating | 0.8mm | UL94 | HB |
Hot filament ignition temperature | 0.8mm | IEC60695-2-13 | 725 °C |
physical property | Test Condition | Test Method | AKRO-PLASTIC GERMANY/B3 GF 15 1 L BK |
---|---|---|---|
Shrinkage rate | TD | ISO294-4 | 0.90 % |
SpiralFlow2.3 | 内部方法 | 100 CM | |
Melt volume flow rate | 275°C/5.0kg | ISO1133 | 15.0 cm3/10min |
HumidityAbsorption-62%RH | 70°C | ISO1110 | 1.7 % |
Shrinkage rate | MD | ISO294-4 | 0.50 % |
Thermal performance | Test Condition | Test Method | AKRO-PLASTIC GERMANY/B3 GF 15 1 L BK |
---|---|---|---|
0.45MPa,未退火 | ISO75-2/B | 215 °C | |
1.8MPa,未退火 | ISO75-2/A | 192 °C | |
Melting temperature 5 | DINEN11357-1 | 220 °C |