Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

ABS AS1003FR BK-038-5 SABIC INNOVATIVE US
LNP™ FARADEX™
Plastic bag、Electronic and Electrical
Conductive
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | SABIC INNOVATIVE US/AS1003FR BK-038-5 |
---|---|---|---|
Suspended wall beam without notch impact strength | 23°C | ISO 180/1U | 18 kJ/m² |
Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 7.0 kJ/m² |
Dart impact | 23°C,EnergyatPeakLoad | ASTM D3763 | 15.0 J |
Electrical performance | Test Condition | Test Method | SABIC INNOVATIVE US/AS1003FR BK-038-5 |
---|---|---|---|
Volume resistivity | ASTM D257 | 1E+04 ohms·cm | |
Surface Resistivity | ASTM D257 | 10to1.0E+3 ohms | |
Shielding effectiveness (EMI) | 3.00mm | 内部方法 | 50to65 dB |
Mechanical properties | Test Condition | Test Method | SABIC INNOVATIVE US/AS1003FR BK-038-5 |
---|---|---|---|
Tensile modulus | ISO 527-2/1 | 2700 Mpa | |
elongation | 屈服 | ASTM D638 | 2.6 % |
bending strength | ASTM D790 | 75.8 Mpa | |
Tensile strain | 屈服 | ISO 527-2 | 2.2 % |
tensile strength | 断裂 | ASTM D638 | 39.3 Mpa |
断裂 | ISO 527-2 | 37.0 Mpa | |
Flexural modulus | ASTM D790 | 3050 Mpa | |
Tensile modulus | ASTM D638 | 3160 Mpa | |
elongation | 断裂 | ASTM D638 | 6.2 % |
bending strength | ISO 178 | 66.0 Mpa | |
Tensile strain | 断裂 | ISO 527-2 | 2.8 % |
Flexural modulus | ISO 178 | 2800 Mpa | |
tensile strength | 屈服 | ASTM D638 | 42.1 Mpa |
屈服 | ISO 527-2 | 38.0 Mpa |
physical property | Test Condition | Test Method | SABIC INNOVATIVE US/AS1003FR BK-038-5 |
---|---|---|---|
Shrinkage rate | MD:24小时 | ISO 294-4 | 0.27 % |
MD:24小时 | ASTM D955 | 0.30 % | |
Water absorption rate | 24hr,50%RH | ASTM D570 | 0.20 % |
Shrinkage rate | TD:24hr | ASTM D955 | 0.40 % |
TD:24小时 | ISO 294-4 | 0.39 % |
Thermal performance | Test Condition | Test Method | SABIC INNOVATIVE US/AS1003FR BK-038-5 |
---|---|---|---|
Heat distortion temperature | 0.45MPa,Unannealed,64.0mmSpan,HDT | ISO 75-2/Bf | 93.0 °C |
Linear coefficient of thermal expansion | TD:-40到40°C | ASTME831 | 6.3E-05 cm/cm/°C |
TD:-40到40°C | ISO 11359-2 | 9.3E-05 cm/cm/°C | |
Heat distortion temperature | 0.45MPa,未退火,3.20mm,HDT | ASTM D648 | 96.7 °C |
Linear coefficient of thermal expansion | MD:-40到40°C | ASTME831 | 7.7E-05 cm/cm/°C |
MD:-40到40°C | ISO 11359-2 | 7.1E-05 cm/cm/°C | |
Heat distortion temperature | 1.8MPa,未退火,64.0mm跨距,HDT | ISO 75-2/Af | 78.0 °C |
1.8MPa,未退火,3.20mm,HDT | ASTM D648 | 88.3 °C |
Contact Us
Get App