Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PEEK 150G VICTREX UK
VICTREX®
--
--
UL
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | VICTREX UK/150G |
---|---|---|---|
Suspended wall beam without notch impact strength | 23°C | ISO 180 | 25 kJ/m² |
Impact strength of cantilever beam gap | 23°C | ISO 180/A | 6.0 kJ/m² |
hardness | Test Condition | Test Method | VICTREX UK/150G |
---|---|---|---|
Shore hardness | 邵氏D,23°C | ISO 868 | 86 |
Mechanical properties | Test Condition | Test Method | VICTREX UK/150G |
---|---|---|---|
Tensile strain | 断裂,23°C | ISO 527-2 | 2.4 % |
bending strength | 23°C | ISO 178 | 215 Mpa |
Flexural modulus | 23°C | ISO 178 | 7300 Mpa |
Tensile modulus | 23°C | ISO 527-2 | 7500 Mpa |
tensile strength | 断裂,23°C | ISO 527-2 | 135 Mpa |
Electrical performance | Test Condition | Test Method | VICTREX UK/150G |
---|---|---|---|
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 4 | |
Volume resistivity | IEC 60093 | 1E+16 ohms·cm | |
dielectric strength | 2.00mm | IEC 60243-1 | 23 KV/mm |
Filling analysis | Test Condition | Test Method | VICTREX UK/150G |
---|---|---|---|
melt viscosity | 400°C | ISO 11443 | 200 Pa·s |
physical property | Test Condition | Test Method | VICTREX UK/150G |
---|---|---|---|
Shrinkage rate | TD | ISO 294-4 | 1.0 % |
MD | ISO 294-4 | 0.40 % | |
spiral flow length | 内部方法 | 18.0 CM | |
density | 比重 | ISO 1183 | 1.40 g/cm³ |
Water absorption rate | 100°C,饱和 | ISO 62 | 0.50 % |
饱和,23°C | ISO 62 | 0.40 % |
Thermal performance | Test Condition | Test Method | VICTREX UK/150G |
---|---|---|---|
Heat distortion temperature | 1.8MPa,未退火,HDT | ISO 75-2/Af | 323 °C |
melting temperature | ISO 11357-3 | 343 °C | |
Linear coefficient of thermal expansion | MD:>143°C | ISO 11359-2 | 3E-05 cm/cm/°C |
thermal conductivity | 23°C9 | ISO 22007-4 | 0.30 W/m/K |
Linear coefficient of thermal expansion | MD:<143°C | ISO 11359-2 | 3E-05 cm/cm/°C |
thermal conductivity | 23°C10 | ISO 22007-4 | 0.35 W/m/K |
Glass Transition Temperature | --8 | ISO 11357-2 | 147 °C |
Linear coefficient of thermal expansion | TD:>143°C | ISO 11359-2 | 1.2E-04 cm/cm/°C |
Glass Transition Temperature | --7 | ISO 11357-2 | 143 °C |
Linear coefficient of thermal expansion | TD:<143°C | ISO 11359-2 | 5.5E-05 cm/cm/°C |
Contact Us