POM
POM M90
Injection grade
mechanical propertiesTest ConditionTest Method/M90
Tensile modulusISO 527-2/1A/12750 MPa
tensile strengthBreak,23℃ASTM D63860.7 MPa
YieldISO 527-2/1A/5063 MPa
Impact strength of simply supported beam without notch-30℃ISO 179/1eA4 kJ/m²
Tensile strainYieldISO 527-2/1A/5010 %
Bending modulus23℃ISO 1782490 MPa
thermal performanceTest ConditionTest Method/M90
Linear coefficient of thermal expansionflowISO 11359-20.00011 cm/cm/℃
Hot deformation temperature1.8MPa,UnannealedASTM D648110
Linear coefficient of thermal expansionTransverseISO 11359-20.00012 cm/cm/℃
Hot deformation temperature1.8MPa,UnannealedISO 75-2/A91
Vicat softening temperatureISO 306/B50161
Basic PerformanceTest ConditionTest Method/M90
Shrinkage rateAcross flowISO 294-41.7 %
melt mass-flow rate190℃/2.16kgISO 11338 cm³/10min
densityASTM D7921.41 g/cm³
Shrinkage rateAcross flowASTM D9551.8 %
flowISO 294-41.9 %
flowASTM D9552.2 %