Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PEI HU1000 2H4D342 SABIC INNOVATIVE US
ULTEM™
Medical devices,Medical and nursing supplies
Middle flow,Biocompatibility,Steam sterilization
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
thermal performance | Test Condition | Test Method | SABIC INNOVATIVE US/HU1000 2H4D342 |
---|---|---|---|
Hot deformation temperature | 1.8MPa,Unannealed,6.40mm | ASTM D648 | 201 °C |
1.8MPa,Unannealed,64.0mmSpan | ISO 75-2/Af | 215 °C | |
Linear coefficient of thermal expansion | TD:-40to40°C | ISO 11359-2 | 5E-05 cm/cm/°C |
TD:-20to150°C | ASTME831 | 5.4E-05 cm/cm/°C | |
MD:-20to150°C | ASTME831 | 5.6E-05 cm/cm/°C | |
MD:-40to40°C | ISO 11359-2 | 5E-05 cm/cm/°C | |
Vicat softening temperature | -- | ISO 306/B120 | 211 °C |
ASTM D152510 | 219 °C | ||
-- | ISO 306/B50 | 215 °C |
mechanical properties | Test Condition | Test Method | SABIC INNOVATIVE US/HU1000 2H4D342 |
---|---|---|---|
Bending modulus | 50.0mmSpan | ASTM D790 | 3440 Mpa |
ISO 178 | 3300 Mpa | ||
bending strength | Yield,50.0mmSpan | ASTM D790 | 173 Mpa |
ISO 178 | 160 Mpa | ||
elongation | Break | ASTM D638 | 60 % |
Yield | ASTM D638 | 7.0 % | |
Tensile modulus | ASTM D638 | 3580 Mpa | |
ISO 527-2/1 | 3200 Mpa | ||
Tensile strain | Break | ISO 527-2/5 | 60 % |
Yield | ISO 527-2/5 | 6.0 % | |
tensile strength | Break | ISO 527-2/5 | 85.0 Mpa |
Yield | ASTM D638 | 110 Mpa | |
Yield | ISO 527-2/5 | 105 Mpa | |
Break | ASTM D638 | 90.0 Mpa |
Electrical performance | Test Condition | Test Method | SABIC INNOVATIVE US/HU1000 2H4D342 |
---|---|---|---|
Arc resistance | ASTM D495 | PLC 5 | |
Compared to the anti leakage trace index | CTI | UL 746 | PLC 4 |
Dielectric constant | 1kHz | ASTM D150 | 3.15 |
Dielectric strength | 1.60mm,inAir | ASTM D149 | 33 KV/mm |
1.60mm,in Oil | ASTM D149 | 28 KV/mm | |
Dissipation factor | 1kHz | ASTM D150 | 1.3E-03 |
2.45GHz | ASTM D150 | 2.5E-03 | |
High arc combustion index | HAI | UL 746 | PLC 3 |
High voltage arc tracing rate | HVTR | UL 746 | PLC 2 |
Hot wire ignition | HWI | UL 746 | PLC 1 |
Volume resistivity | ASTM D257 | 1E+17 ohms·cm |
Physical properties | Test Condition | Test Method | SABIC INNOVATIVE US/HU1000 2H4D342 |
---|---|---|---|
melt mass-flow rate | 337°C/6.6kg | ASTM D1238 | 9.0 g/10min |
Melt Volume Flow Rate (MVR) | 220°C/5.0kg | ISO 1133 | 13.0 cm3/10min |
Shrinkage rate | MD:3.20mm | Internal Method | 0.50-0.70 % |
Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.70 % |
Saturation,23°C | ISO 62 | 1.3 % | |
24hr | ASTM D570 | 0.25 % | |
Equilibrium,23°C | ASTM D570 | 1.3 % |
impact performance | Test Condition | Test Method | SABIC INNOVATIVE US/HU1000 2H4D342 |
---|---|---|---|
Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 4.0 kJ/m² |
Impact strength of cantilever beam gap | -30°C | ISO 180/1A | 6.0 kJ/m² |
23°C | ISO 180/1A | 6.0 kJ/m² |
flammability | Test Condition | Test Method | SABIC INNOVATIVE US/HU1000 2H4D342 |
---|---|---|---|
Extreme Oxygen Index | ASTM D2863 | 47 % | |
NBSSmokeDensity-Flaming,Ds,4min | ASTME662 | 0.700 |