plas

Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PEI HU1000 2H4D342 SABIC INNOVATIVE US
ULTEM™ 
Medical devices,Medical and nursing supplies
Middle flow,Biocompatibility,Steam sterilization
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

thermal performanceTest ConditionTest MethodSABIC INNOVATIVE US/HU1000 2H4D342
Hot deformation temperature1.8MPa,Unannealed,6.40mmASTM D648201 °C
1.8MPa,Unannealed,64.0mmSpanISO 75-2/Af215 °C
Linear coefficient of thermal expansionTD:-40to40°CISO 11359-25E-05 cm/cm/°C
TD:-20to150°CASTME8315.4E-05 cm/cm/°C
MD:-20to150°CASTME8315.6E-05 cm/cm/°C
MD:-40to40°CISO 11359-25E-05 cm/cm/°C
Vicat softening temperature--ISO 306/B120211 °C
ASTM D152510219 °C
--ISO 306/B50215 °C
mechanical propertiesTest ConditionTest MethodSABIC INNOVATIVE US/HU1000 2H4D342
Bending modulus50.0mmSpanASTM D7903440 Mpa
ISO 1783300 Mpa
bending strengthYield,50.0mmSpanASTM D790173 Mpa
ISO 178160 Mpa
elongationBreakASTM D63860 %
YieldASTM D6387.0 %
Tensile modulusASTM D6383580 Mpa
ISO 527-2/13200 Mpa
Tensile strainBreakISO 527-2/560 %
YieldISO 527-2/56.0 %
tensile strengthBreakISO 527-2/585.0 Mpa
YieldASTM D638110 Mpa
YieldISO 527-2/5105 Mpa
BreakASTM D63890.0 Mpa
Electrical performanceTest ConditionTest MethodSABIC INNOVATIVE US/HU1000 2H4D342
Arc resistanceASTM D495PLC 5
Compared to the anti leakage trace indexCTIUL 746PLC 4
Dielectric constant1kHzASTM D1503.15
Dielectric strength1.60mm,inAirASTM D14933 KV/mm
1.60mm,in OilASTM D14928 KV/mm
Dissipation factor1kHzASTM D1501.3E-03
2.45GHzASTM D1502.5E-03
High arc combustion indexHAIUL 746PLC 3
High voltage arc tracing rateHVTRUL 746PLC 2
Hot wire ignitionHWIUL 746PLC 1
Volume resistivityASTM D2571E+17 ohms·cm
Physical propertiesTest ConditionTest MethodSABIC INNOVATIVE US/HU1000 2H4D342
melt mass-flow rate337°C/6.6kgASTM D12389.0 g/10min
Melt Volume Flow Rate (MVR)220°C/5.0kgISO 113313.0 cm3/10min
Shrinkage rateMD:3.20mmInternal Method0.50-0.70 %
Water absorption rateEquilibrium,23°C,50%RHISO 620.70 %
Saturation,23°CISO 621.3 %
24hrASTM D5700.25 %
Equilibrium,23°CASTM D5701.3 %
impact performanceTest ConditionTest MethodSABIC INNOVATIVE US/HU1000 2H4D342
Charpy Notched Impact Strength23°CISO 179/1eA4.0 kJ/m²
Impact strength of cantilever beam gap-30°CISO 180/1A6.0 kJ/m²
23°CISO 180/1A6.0 kJ/m²
flammabilityTest ConditionTest MethodSABIC INNOVATIVE US/HU1000 2H4D342
Extreme Oxygen IndexASTM D286347 %
NBSSmokeDensity-Flaming,Ds,4minASTME6620.700