Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA/MXD6 1371 BLK01 MITSUBISHI ENGINEERING JAPAN
RENY™
Electronic and Electrical Applications,Automotive sector
High rigidity,High impact,Filler: Glass fiber reinf,55% filler by weight
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
thermal performance | Test Condition | Test Method | MITSUBISHI ENGINEERING JAPAN/1371 BLK01 |
---|---|---|---|
Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 236 °C |
1.8MPa,Unannealed | ISO 75-2/A | 227 °C |
mechanical properties | Test Condition | Test Method | MITSUBISHI ENGINEERING JAPAN/1371 BLK01 |
---|---|---|---|
Bending modulus | ISO 178 | 19600 Mpa | |
bending strength | ISO 178 | 403 Mpa | |
Tensile modulus | ISO 527-2 | 20800 Mpa | |
Tensile strain | Break | ISO 527-2 | 1.9 % |
tensile strength | Break | ISO 527-2 | 242 Mpa |
Physical properties | Test Condition | Test Method | MITSUBISHI ENGINEERING JAPAN/1371 BLK01 |
---|---|---|---|
Shrinkage rate | 0.40 % | ||
Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.90 % |
Saturation,23°C | ISO 62 | 0.11 % |
impact performance | Test Condition | Test Method | MITSUBISHI ENGINEERING JAPAN/1371 BLK01 |
---|---|---|---|
Impact strength of simply supported beam without notch | 23°C | ISO 179 | 93 kJ/m² |
flammability | Test Condition | Test Method | MITSUBISHI ENGINEERING JAPAN/1371 BLK01 |
---|---|---|---|
UL flame retardant rating | 1.6mm | UL 94 | HB |
-- | UL 94 | HB |