Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PC/ASA C2950-7T1D300 SABIC INNOVATIVE NANSHA
CYCOLOY™
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | SABIC INNOVATIVE NANSHA/C2950-7T1D300 |
---|---|---|---|
Instrumented dart impact energy -30 ℃ (-22 ℉) peak | ASTM D3763 | 54 J | |
ASTM D3763 | 61 J | ||
Izod Notched at 23 ℃ (73 ℉) | ASTM D256 | 534 J/m | |
Izod Notched -30 ℃ (-22 ℉) | ASTM D256 | 160 J/m |
hardness | Test Condition | Test Method | SABIC INNOVATIVE NANSHA/C2950-7T1D300 |
---|---|---|---|
Rockwell hardness R | ASTM D785 | 123 R |
Electrical Property | Test Condition | Test Method | SABIC INNOVATIVE NANSHA/C2950-7T1D300 |
---|---|---|---|
High Voltage Arc Traceability Rate (HVTR) | UL 746A | 2 plc | |
High current arc ignition (HAI) | UL 746A | 0 plc | |
Dielectric Strength | in oil, 3.2 | ASTM D149 | 19.5 kV/mm |
Volume resistivity | ASTM D257 | 100000000000000000 ohm-cm | |
dielectric constant | ASTM D 150 | 3 | |
Surface Resistivity | ASTM D257 | 10000000000000000 Ohm | |
Dissipation Factor | ASTM D 150 | 49 E-4 | |
Compared to the Leakage Traceability Index (CTI) | UL 746A | 0 plc | |
arc resistance | ASTM D495 | 6 plc | |
UL 746A | 1 plc |
Mechanical properties | Test Condition | Test Method | SABIC INNOVATIVE NANSHA/C2950-7T1D300 |
---|---|---|---|
2.6 mm/ | ASTM D790 | 102 Mpa | |
Type I, 50 | ASTM D638 | 40 | |
Tensile strength yield (yld) | Type I, 50 | ASTM D638 | 62 Mpa |
Flexural modulus | 2.6 mm/ | ASTM D790 | 2650 Mpa |
combustibility | Test Condition | Test Method | SABIC INNOVATIVE NANSHA/C2950-7T1D300 |
---|---|---|---|
UL fire rating 5VB | UL94 | 2.49 mm | |
ASTM D 2863 | 32 % | ||
UL fire rating V-0 | UL94 | 1.5 mm |
Thermal Properties | Test Condition | Test Method | SABIC INNOVATIVE NANSHA/C2950-7T1D300 |
---|---|---|---|
Vicat softening temperature | Rate B/50 | ASTM D1525 | 85 °C |
Relative Temperature Index (RTI) intensity w/o impact- | UL 746B | 85 °C | |
Coefficient of Linear Expansion (CLTE) Across Flow | -30°C to 3 | ASTM E831 | 72 E-6/°C |
Relative Temperature Index (RTI) impact w/impact- | UL 746B | 85 °C | |
Coefficient of Linear Expansion (CLTE) Longitudinal (Flow) | -30°C to 3 | ASTM E831 | 72 E-6/°C |
thermal conductivity | ASTM C 177 | 0.2 W/m-°C | |
Relative Temperature Index (RTI) Electrical Elec- | UL 746B | 85 °C |
physical property | Test Condition | Test Method | SABIC INNOVATIVE NANSHA/C2950-7T1D300 |
---|---|---|---|
Water absorption rate | 24 hours | ASTM D570 | 0.1 |
Melt Mass Flow Rate (MFR) 260 ° C/2.16 kg | ASTM D1238 | 10 g/10min | |
Longitudinal shrinkage rate (Flow) | xflow, 3.2 | Internal | 0.4~0.6 |
Water absorption rate | flow, 3.2 | ASTM D570 | 0.4 |
Longitudinal shrinkage rate (Flow) | flow, 3.2 | Internal | 0.4~0.8 |