Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PA12 L2101F EVONIK GERMANY
VESTAMID®
Cable sheath、Automotive Applications
Low temperature impact re、Resistance to stress crac、Fatigue resistance
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

Impact resistanceTest ConditionTest MethodEVONIK GERMANY/L2101F
Charpy Notched Impact Strength23°C,完全断裂ISO 179/1eA32 kJ/m²
Impact strength of simply supported beam without notch-30°CISO 179/1eUNoBreak
23°CISO 179/1eUNoBreak
Charpy Notched Impact Strength-30°C,完全断裂ISO 179/1eA9.0 kJ/m²
Supplementary InformationTest ConditionTest MethodEVONIK GERMANY/L2101F
electrolytic corrosionIEC 60426A1
ISO ShortcutISO 1874PA12.F.22-010
Electrical performanceTest ConditionTest MethodEVONIK GERMANY/L2101F
dielectric strengthIEC 60243-129 KV/mm
Compared to the Leakage Tracking Index (CTI)--IEC 60112 V
Volume resistivityIEC 600931E+15 ohms·cm
Compared to the Leakage Tracking Index (CTI)SolutionA3IEC 60112 V
relative permittivity23°C,1MHzIEC 602503.00
23°C,100HzIEC 602503.70
Dissipation Factor23°C,100HzIEC 602500.045
23°C,1MHzIEC 602500.028
Mechanical propertiesTest ConditionTest MethodEVONIK GERMANY/L2101F
Tensile modulusISO 527-21400 Mpa
Tensile strain断裂ISO 527-2>50 %
屈服ISO 527-25.0 %
tensile strength 屈服ISO 527-245.0 Mpa
flammabilityTest ConditionTest MethodEVONIK GERMANY/L2101F
UL flame retardant rating3.2mmUL 94HB
1.6mmUL 94HB
physical property Test ConditionTest MethodEVONIK GERMANY/L2101F
density23°CISO 11831.01 g/cm³
Shrinkage rateTDISO 294-41.3 %
MDISO 294-40.70 %
Water absorption rate平衡,23°C,50%RHISO 620.80 %
饱和,23°CISO 621.6 %
Thermal performanceTest ConditionTest MethodEVONIK GERMANY/L2101F
melting temperatureISO 11357-3178 °C
Linear coefficient of thermal expansionMD:23到55°CISO 11359-21.5E-04 cm/cm/°C
Heat distortion temperature0.45MPa,未退火,HDTISO 75-2/B110 °C
1.8MPa,未退火,HDTISO 75-2/A50.0 °C
vicat--ISO 306/B140 °C
--ISO 306/A170 °C

Contact Us

Get App