PA46 OCD2100-BK27021 DSM HOLAND
Stanyl®
Home appliance components,Electronic and electrical components
Glass fiber reinforced,Thermal stability
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| thermal performance | Test Condition | Test Method | DSM HOLAND/OCD2100-BK27021 |
|---|---|---|---|
| Hot deformation temperature | 0.45 MPa, Unannealed | ISO 75-2/B | 270 °C |
| 1.8 MPa, Unannealed | ISO 75-2/A | 256 °C | |
| Linear coefficient of thermal expansion | Across Flow | ISO 11359-2 | 5.0E-5 cm/cm/°C |
| Flow | ISO 11359-2 | 2.5E-5 cm/cm/°C | |
| Melting temperature | ISO 11357-3 | 282 °C |
| mechanical properties | Test Condition | Test Method | DSM HOLAND/OCD2100-BK27021 |
|---|---|---|---|
| Bending modulus | -- | ISO 178 | 13000 Mpa |
| 200°C | ISO 178 | 3400 Mpa | |
| 120°C | ISO 178 | 5000 Mpa | |
| 160°C | ISO 178 | 4600 Mpa | |
| 180°C | ISO 178 | 4200 Mpa | |
| Tensile modulus | 200°C | ISO 527-2 | 3400 Mpa |
| -- | ISO 527-2 | 13000 Mpa | |
| 120°C | ISO 527-2 | 5000 Mpa | |
| 160°C | ISO 527-2 | 4600 Mpa | |
| 180°C | ISO 527-2 | 4200 Mpa | |
| Tensile strain | Break, 180°C | ISO 527-2 | 12 % |
| Break, 160°C | ISO 527-2 | 11 % | |
| Break, 120°C | ISO 527-2 | 10 % | |
| Break | ISO 527-2 | 3.0 % | |
| Break, 200°C | ISO 527-2 | 13 % | |
| tensile strength | Break, 120°C | ISO 527-2 | 100 Mpa |
| Break, 200°C | ISO 527-2 | 60.0 Mpa | |
| Break | ISO 527-2 | 210 Mpa | |
| Break, 180°C | ISO 527-2 | 75.0 Mpa | |
| Break, 160°C | ISO 527-2 | 85.0 Mpa |
| Electrical performance | Test Condition | Test Method | DSM HOLAND/OCD2100-BK27021 |
|---|---|---|---|
| Compared to the anti leakage trace index | IEC 60112 | V |
| Physical properties | Test Condition | Test Method | DSM HOLAND/OCD2100-BK27021 |
|---|---|---|---|
| Shrinkage rate | 横向Flow | ISO 294-4 | 1.0 % |
| Flow | ISO 294-4 | 0.50 % | |
| Water absorption rate | Equilibrium, 23°C, 50% RH | ISO 62 | 2.2 % |
| impact performance | Test Condition | Test Method | DSM HOLAND/OCD2100-BK27021 |
|---|---|---|---|
| Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 65 kJ/m² |
| 23°C | ISO 179/1eU | 90 kJ/m² |