Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA6T HTN52G35HSL NC010 DUPONT USA
Zytel®
Fitness equipment、Electrical appliances、Car exterior decoration
High temperature resistan、Glass fiber reinforced
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Mechanical properties | Test Condition | Test Method | DUPONT USA/HTN52G35HSL NC010 |
---|---|---|---|
Charpy Notched Impact Strength | -30°C | ISO 179/1eA | 7 kJ/m² |
23°C | ISO 179/1eA | 8 kJ/m² | |
Flexural modulus | 23°C | ISO 178 | 10300 Mpa |
Tensile modulus | 23°C | ISO 527-2 | 11600 Mpa |
Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 40 kJ/m² |
elongation at break | 23°C | ISO 527-2 | 2.10 % |
Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 45 kJ/m² |
tensile strength | 23°C | ISO 527-2 | 187 Mpa |
Electrical performance | Test Condition | Test Method | DUPONT USA/HTN52G35HSL NC010 |
---|---|---|---|
dielectric strength | 0.250mm | IEC 60243-1 | 28 KV/mm |
Volume resistivity | IEC 60093 | 1E+14 Ω.cm |
Flame retardant performance | Test Condition | Test Method | DUPONT USA/HTN52G35HSL NC010 |
---|---|---|---|
Relative temperature of heating wire | 0.75mm | IEC 60695-2-13 | 750 °C |
GWIT | 3.00mm | IEC 60695-2-12 | 775 °C |
Relative temperature of heating wire | 3.00mm | IEC 60695-2-13 | 850 °C |
GWIT | 0.75mm | IEC 60695-2-12 | 775 °C |
Relative temperature of heating wire | 1.50mm | IEC 60695-2-13 | 700 °C |
UL flame retardant rating | UL -94 | HB 1.50mm | |
UL -94 | HB 3.00mm | ||
UL -94 | HB 0.75mm | ||
GWIT | 1.50mm | IEC 60695-2-12 | 725 °C |
physical property | Test Condition | Test Method | DUPONT USA/HTN52G35HSL NC010 |
---|---|---|---|
Shrinkage rate | TD | ISO 294-4 | 0.90 % |
MD | ISO 294-4 | 0.30 % |
Thermal performance | Test Condition | Test Method | DUPONT USA/HTN52G35HSL NC010 |
---|---|---|---|
Heat distortion temperature | 1.80MPa退火,HDT | ISO 75-2/Af | 285 °C |
vicat | 熔融温度 | ISO 11357-3 | 310 °C |
Linear coefficient of thermal expansion | MD | ISO 11359-2 | 2.1E-05 cm/cm/°C |
TD | ISO 11359-2 | 6.7E-05 cm/cm/°C |
Contact Us
Get App