Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA6 BS/2 EMS-CHEMIE SWITZERLAND
Grilon®
Automotive sector,Electronic field,Electrical field,Industrial applications,Engineering accessories,Home appliance components,sporting goods,Household goods,automotive industry ,electrical machinery,electron,motion,Leisure and mechanical engineering fields
Flame retardant,Excellent appearance
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Other performance | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/BS/2 |
---|---|---|---|
Limiting Oxygen Index (LOI) | ISO 4589-2 | >32 % |
Basic Performance | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/BS/2 |
---|---|---|---|
density | dry | ISO 1183 | 1.16 dry |
Water absorption rate | 23℃ | ISO 62 | 8.0 % |
23℃/50%rh | ISO 62 | 0.85 % |
thermal performance | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/BS/2 |
---|---|---|---|
Heating wire temperature | 1-3mm | ISO 11359-2 | 960 °C |
Hot deformation temperature | 0.45MPa,dry | ISO 75 | 185 °C |
1.80MPa,dry | ISO 75 | 65 °C | |
Linear coefficient of thermal expansion | 23-55℃,dry,Across Flow | ISO 11359 | 0.7 |
23-55℃,dry(Across Flow) | ISO 11359 | 0.9 | |
Maximum operating temperature | long term,dry | ISO 2578 | 100-120 °C |
short term,dry | ISO 2578 | 180 °C | |
Melting temperature | DSC,dry | ISO 11357 | 222 °C |
UL flame retardant rating | 0.40-0.32mm | ISO 1210 | V-0 rating |
mechanical properties | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/BS/2 |
---|---|---|---|
Elongation at Break | 50mm/min(dry,cond) | ISO 527 | 4(>50) % |
Impact strength of cantilever beam gap | Charpy,23℃(dry,cond) | ISO 179/1eA | 3(15) KJ/m |
Charpy,23℃(dry,cond) | ISO 179/1eU | >100(>100) KJ/m | |
Tensile modulus | 1mm/min,(dry,cond) | ISO 527 | 3700(1200) Mpa |
tensile strength | 50mm/min(dry,cond),Break | ISO 527 | 70(-) Mpa |
Yield,50mm/min(dry,cond) | ISO 527 | 90(45) Mpa |
Electrical performance | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/BS/2 |
---|---|---|---|
Arc resistance | cond | IEC 60112 | 575 |
Dielectric constant | 100Hz,dry,cond | IEC 60250 | 3.0(8.0) |
1MHz,dry,cond | IEC 60250 | 4.0(4.0) | |
Dielectric loss | 1MHz,dry,cond | IEC 60250 | 200(850) |
100Hz,dry,cond | IEC 60250 | 30(1000) | |
Dielectric strength | dry,cond | IEC 60243-1 | 32(29) KV/mm |
Surface resistivity | cond | IEC 60093 | 10 Ω |
Volume resistivity | dry,cond | IEC 60093 | 10 Ω.cm |
Physical properties | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/BS/2 |
---|---|---|---|
Shrinkage rate | trans,Across Flow,dry | ISO 294 | 0.90 % |
long,Across Flow | ISO 294 | 0.85 % |