Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA6 BS/2 EMS-CHEMIE SWITZERLAND
Grilon®
Automotive sector、Electronic field、Electrical field、Industrial applications、Engineering accessories、Home appliance components、sporting goods、Household goods、automotive industry 、electrical machinery、electron、motion、Leisure and mechanical en
Flame retardant、Excellent appearance
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Other performance | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/BS/2 |
---|---|---|---|
Limiting Oxygen Index (LOI) | ISO 4589-2 | >32 % |
Basic performance | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/BS/2 |
---|---|---|---|
density | dry | ISO 1183 | 1.16 g/cm |
Water absorption rate | 23℃/50%rh | ISO 62 | 0.85 % |
23℃ | ISO 62 | 8.0 % |
Mechanical properties | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/BS/2 |
---|---|---|---|
elongation at break | 50mm/min(dry,cond) | ISO 527 | 4(>50) % |
Impact strength of cantilever beam gap | Charpy,23℃(dry,cond) | ISO 179/1eU | >100(>100) KJ/m |
tensile strength | 屈服,50mm/min(dry,cond) | ISO 527 | 90(45) Mpa |
50mm/min(dry,cond),断裂 | ISO 527 | 70(-) Mpa | |
Impact strength of cantilever beam gap | Charpy,23℃(dry,cond) | ISO 179/1eA | 3(15) KJ/m |
Tensile modulus | 1mm/min,(dry,cond) | ISO 527 | 3700(1200) Mpa |
Electrical performance | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/BS/2 |
---|---|---|---|
dielectric constant | 100Hz,dry,cond | IEC 60250 | 3.0(8.0) |
Surface Resistivity | cond | IEC 60093 | 10 Ω |
Dielectric loss | 1MHz,dry,cond | IEC 60250 | 200(850) |
dielectric strength | dry,cond | IEC 60243-1 | 32(29) KV/mm |
dielectric constant | 1MHz,dry,cond | IEC 60250 | 4.0(4.0) |
Dielectric loss | 100Hz,dry,cond | IEC 60250 | 30(1000) |
Volume resistivity | dry,cond | IEC 60093 | 10 Ω.cm |
arc resistance | cond | IEC 60112 | 575 |
physical property | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/BS/2 |
---|---|---|---|
Shrinkage rate | trans,横向,dry | ISO 294 | 0.90 % |
long,纵向 | ISO 294 | 0.85 % |
Thermal performance | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/BS/2 |
---|---|---|---|
maximum service temperature | short term,dry | ISO 2578 | 180 °C |
Heating wire temperature | 1-3mm | ISO 11359-2 | 960 °C |
Linear coefficient of thermal expansion | 23-55℃,dry,纵向 | ISO 11359 | 0.7 |
maximum service temperature | long term,dry | ISO 2578 | 100-120 °C |
Heat distortion temperature | 0.45MPa,dry,HDT | ISO 75 | 185 °C |
UL flame retardant rating | 0.40-0.32mm | ISO 1210 | V-0 rating |
Linear coefficient of thermal expansion | 23-55℃,dry(横向) | ISO 11359 | 0.9 |
Heat distortion temperature | 1.80MPa,dry,HDT | ISO 75 | 65 °C |
melting temperature | DSC,dry | ISO 11357 | 222 °C |
Contact Us
Get App
Top