Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA66 ARV300RKC 106 NT RADICI SUZHOU
Radilon®
--
Filler: Glass fiber reinf,30% filler by weight
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
thermal performance | Test Condition | Test Method | RADICI SUZHOU/ARV300RKC 106 NT |
---|---|---|---|
Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/Af | 245 °C |
0.45MPa,Unannealed | ISO 75-2/Bf | 255 °C | |
Melting temperature | ISO 11357 | 260 °C | |
Vicat softening temperature | ISO 306/B50 | 250 °C |
mechanical properties | Test Condition | Test Method | RADICI SUZHOU/ARV300RKC 106 NT |
---|---|---|---|
Bending modulus | ISO 178 | 8900 Mpa | |
bending strength | ISO 178 | 290 Mpa | |
Tensile modulus | ISO 527-2/1A/1 | 9800 Mpa | |
Tensile strain | Break | ISO 527-2/1A/5 | 3.6 % |
tensile strength | Break | ISO 527-2/1A/5 | 190 Mpa |
Electrical performance | Test Condition | Test Method | RADICI SUZHOU/ARV300RKC 106 NT |
---|---|---|---|
Compared to the anti leakage trace index | IEC 60112 | V | |
Surface resistivity | IEC 60093 | 1E+12 ohms | |
Volume resistivity | IEC 60093 | 1E+15 ohms·cm |
Physical properties | Test Condition | Test Method | RADICI SUZHOU/ARV300RKC 106 NT |
---|---|---|---|
Shrinkage rate | MD | ISO 294-4 | 0.50 % |
TD | ISO 294-4 | 1.2 % | |
Water absorption rate | Equilibrium,23°C,2.00mm,50%RH | ISO 62 | 1.6 % |
Saturation,23°C,2.00mm | ISO 62 | 6.2 % |
impact performance | Test Condition | Test Method | RADICI SUZHOU/ARV300RKC 106 NT |
---|---|---|---|
Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 75 kJ/m² |
23°C | ISO 179/1eU | 90 kJ/m² |
flammability | Test Condition | Test Method | RADICI SUZHOU/ARV300RKC 106 NT |
---|---|---|---|
Burning rate | FMVSS302 | 0.0 mm/min | |
Burning wire flammability index | 2.0mm | IEC 60695-2-12 | 700 °C |
UL flame retardant rating | 0.8mm | UL 94 | HB |