Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA6 F130-C DSM HOLAND
Akulon®
film
Medium viscosity
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| film | Test Condition | Test Method | DSM HOLAND/F130-C |
|---|---|---|---|
| elongation | Break, MD | ISO 527-3 | 350 % |
| Film thickness - tested | 50 µm | ||
| Oxygen permeability | 85% RH : 23°C | ASTM D256A | 38 cm³/m²/bar/24 hr |
| 0% RH : 23°C | ASTM D256A | 26 cm³/m²/bar/24 hr | |
| Tensile modulus | Internal Method | 455 Mpa | |
| Tensile stress | Break,MD | ISO 527-3 | 82.0 Mpa |
| Yield,MD | ISO 527-3 | 31.0 Mpa | |
| Trouser Tear - Parallel | ISO 6383-1 | 32.0 | |
| Water vapor permeability | 23°C, 85% RH | DIS 15106-1/-3 | 35 g/m²/24 hr |
| thermal performance | Test Condition | Test Method | DSM HOLAND/F130-C |
|---|---|---|---|
| Linear coefficient of thermal expansion | Flow | ISO 11359-2 | 9.0E-5 cm/cm/°C |
| Specific heat capacity | 1550 J/kg/°C |
| mechanical properties | Test Condition | Test Method | DSM HOLAND/F130-C |
|---|---|---|---|
| Friction coefficient | Dynamic | ISO 8295 | 1.0 |
| Static | ISO 8295 | 1.2 |
| Physical properties | Test Condition | Test Method | DSM HOLAND/F130-C |
|---|---|---|---|
| Stickiness | ISO 307 | 196 cm³/g |
| Filling analysis | Test Condition | Test Method | DSM HOLAND/F130-C |
|---|---|---|---|
| Average Specific Heat Capacity | 20 to 150°C | 2250 J/kg/°C | |
| Melt viscosity | 260°C | Internal Method | 810000 mPa·s |
| Puncture resistance | Internal Method | 13.0 J/cm | |
| RSV - Formic Acid, 1g/100ml | Internal Method | 3.03 |
| squeeze out | Test Condition | Test Method | DSM HOLAND/F130-C |
|---|---|---|---|
| Oral mold temperature | 270 °C | ||
| Temperature in Zone 1 of the material cylinder | 270 °C | ||
| Temperature in Zone 2 of the material cylinder | 270 °C | ||
| Temperature in Zone 3 of the material cylinder | 270 °C | ||
| Temperature in Zone 4 of the material cylinder | 270 °C | ||
| Traction roller | 110 °C |
| optical performance | Test Condition | Test Method | DSM HOLAND/F130-C |
|---|---|---|---|
| Clarity | Internal Method | 83 % |