Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA66 HTN54G15HSLR DUPONT USA
Zytel®
building materials,Industrial applications,Automotive interior parts,Electronic field,Electrical field
Glass fiber reinforced,Toughening,Filler: Glass fiber reinf,15% filler by weight
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| thermal performance | Test Condition | Test Method | DUPONT USA/HTN54G15HSLR |
|---|---|---|---|
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 277 °C |
| 1.8MPa,Unannealed | ISO 75-2/A | 230 °C | |
| Linear coefficient of thermal expansion | TD:-40to23°C | ISO 11359-2 | 7E-05 cm/cm/°C |
| MD:-- | ISO 11359-2 | 3.4E-05 cm/cm/°C | |
| MD:-40to23°C | ISO 11359-2 | 3.4E-05 cm/cm/°C | |
| TD:-- | ISO 11359-2 | 7.3E-05 cm/cm/°C | |
| Melting temperature | ISO 11357-3 | 300 °C |
| mechanical properties | Test Condition | Test Method | DUPONT USA/HTN54G15HSLR |
|---|---|---|---|
| Bending modulus | ISO 178 | 4900 Mpa | |
| bending strength | ISO 178 | 210 Mpa | |
| Tensile modulus | ISO 527-2 | 5500 Mpa | |
| Tensile strain | Break | ISO 527-2 | 3.5 % |
| tensile strength | Break | ISO 527-2 | 125 Mpa |
| Electrical performance | Test Condition | Test Method | DUPONT USA/HTN54G15HSLR |
|---|---|---|---|
| Volume resistivity | IEC 60093 | 1E+15 ohms·cm |
| Physical properties | Test Condition | Test Method | DUPONT USA/HTN54G15HSLR |
|---|---|---|---|
| density | ISO 1183 | 1.25 g/cm³ | |
| Shrinkage rate | MD | ISO 294-4 | 0.40 % |
| TD | ISO 294-4 | 0.70 % |
| impact performance | Test Condition | Test Method | DUPONT USA/HTN54G15HSLR |
|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 6.0 kJ/m² |
| -40°C | ISO 179/1eA | 5.0 kJ/m² | |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 60 kJ/m² |
| flammability | Test Condition | Test Method | DUPONT USA/HTN54G15HSLR |
|---|---|---|---|
| Burning rate | 1.00mm | ISO 3795 | <100 mm/min |
| FMVSS flammability | FMVSS302 | B | |
| UL flame retardant rating | 0.8mm | IEC 60695-11-10,-20 | HB |
| 1.5mm | IEC 60695-11-10,-20 | HB | |
| 0.8mm | UL 94 | HB | |
| 1.5mm | UL 94 | HB |