Material Properties
Physical | Test Condition | Test Method | Test Result | Unit |
---|
Modeling Shrinkage | | ISO294-4 | 0.50to0.70 | % |
Melt Mass-Flow Rate | 300°C/1.2kg | ASTMD1238 | 10 | g/10min |
Melt Volume flow Rate | 300°C/1.2kg | ISO1133 | 10.0 | cm3/10min |
Density / Specific Gravity | | ASTMD792 | 1.20 | g/cm³ |
Density / Specific Gravity | 23°C | ISO1183 | 1.20 | g/cm³ |
Mechanical | Test Condition | Test Method | Test Result | Unit |
---|
Flexural Stress | | ISO178 | 90.0 | Mpa |
Tensile Elongation | Break | ASTMD638 | 110 | % |
Flexural Modulus | | ISO178 | 2400 | Mpa |
Tensile Strength | Yield | ASTMD638 | 61.6 | Mpa |
Flexural Modulus | | ASTMD790 | 2340 | Mpa |
Flexural Strength | | ASTMD790 | 89.8 | Mpa |
Tensile Stress | Yield | ISO527-2/50 | 65.0 | Mpa |
Tensile Stress | Break | ISO527-2/50 | 75.0 | Mpa |
Tensile Strain | Break | ISO527-2/50 | 120 | % |
Thermal | Test Condition | Test Method | Test Result | Unit |
---|
Coefficient of Linear Thermal Expansion | MD | ISO11359-2 | 6.0E-5to8.0E-5 | cm/cm/°C |
Heat Deflection Temperature | 1.8MPa,Unannealed | ISO75-2/A | 128 | °C |
Heat Deflection Temperature | 1.8MPa,Annealed | ISO75-2/A | 143 | °C |
Vicat Softening Temperature | | ASTMD15257 | 150 | °C |
Vicat Softening Temperature | -- | ISO306/A50 | 150 | °C |
Vicat Softening Temperature | -- | ISO306/B50 | 145 | °C |
Heat Deflection Temperature | 0.45MPa,Annealed | ASTMD648 | 146 | °C |
Impact | Test Condition | Test Method | Test Result | Unit |
---|
Charpy Notched Impact Strength | 23°C | ISO179 | 75 | kJ/m² |
Notched Izod Impact Strength | 23°C,3.20mm | ASTMD256 | 850 | J/m |
Notched Izod Impact Strength | 23°C | ISO180/1A | 75 | kJ/m² |
Hardness | Test Condition | Test Method | Test Result | Unit |
---|
Rockwell Hardness | M-Scale | ASTMD785 | 77 | |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|
Flame Rating | 1.5mm | UL94 | V-2 | |
Flame Rating | 2.5mm | UL94 | V-2 | |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.