Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Modeling Shrinkage | 3.2mm | ASTM D-955 | 2-4 | |
Dissipation Factor | 60Hz | ASTM D-150 | 0.0008 | |
Advance | | | 10 | % |
Density / Specific Gravity | | ASTM D-792 | 1.25 | |
Flame Rating | | UL 94 | V-0 | |
Flame Rating | | UL 94 | 1.5 | mm |
Flame Rating | | UL 94 | 3.0 | mm |
Flame Rating | | UL 94 | 5V | |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Notched Impact Strength | 23°C | ASTM D-256 | 107 | J/m |
Tensile Strength | Yield点 | ASTM D-638 | 66 | Mpa |
Tensile Strength | Break点 | ASTM D-638 | 55 | Mpa |
Tensile Elongation | Break | ASTM D-638 | 15 | % |
Rockwell Hardness | | ASTM D-785 | 124 | |
Flexural Modulus | | ASTM D-790 | 3445 | Mpa |
Flexural Strength | | ASTM D-790 | 103 | Mpa |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Heat Deflection Temperature | 1.8MPa | ASTM D-648 | 142 | °C |
Heat Deflection Temperature | 0.45MPa | ASTM D-648 | 146 | °C |
Vicat Softening Temperature | | ASTM D-1525 | 154 | °C |
Coefficient of Linear Thermal Expansion | | ASTM E-831 | 3.2×10 | 1/°C |
UL Long-Term Service Temperature | | UL 746B | 130 | °C |
Electrical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Dissipation Factor | 1MHz | ASTM D-150 | 0.0075 | |
Dielectric Constant | 60Hz | ASTM D-150 | 3.1 | |
Dielectric Constant | 1MHz | ASTM D-150 | 3.05 | |
Volume Resistivity | | ASTM D-257 | 1.0×10 | Ω.cm |
Physical | Test Condition | Test Method | Test Result | Unit |
---|
Moisture Absorption | | ASTM D-570 | 0.12 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.