Technical Data Sheet
Physical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Density / Specific Gravity | | ASTMD792 | 1.24 | g/cm³ |
Melt Mass-Flow Rate | 343°C/2.16kg | ASTMD1238 | 6.5 | g/10min |
Modeling Shrinkage | MD | ASTMD955 | 0.70 | % |
Moisture Absorption | 24hr | ASTMD570 | 0.30 | % |
Mechanical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Tensile Modulus | | ASTMD638 | 2480 | Mpa |
Tensile Strength | | ASTMD638 | 70.3 | Mpa |
Tensile Elongation | Break | ASTMD638 | 50to100 | % |
Flexural Modulus | | ASTMD790 | 2690 | Mpa |
Flexural Strength | | ASTMD790 | 106 | Mpa |
Thermal Properties | Test Condition | Test Method | Test Result | Unit |
---|
Heat Deflection Temperature | 1.8MPa,Unannealed | ASTMD648 | 174 | °C |
Coefficient of Linear Thermal Expansion | MD | ASTMD696 | 5.6E-05 | cm/cm/°C |
Electrical Properties | Test Condition | Test Method | Test Result | Unit |
---|
Volume Resistivity | | ASTMD257 | 3E+16 | ohms·cm |
Dielectric Strength | | ASTMD149 | 17 | KV/mm |
Dielectric Constant | 60Hz | ASTMD150 | 3.03 | |
Dielectric Constant | 1kHz | ASTMD150 | 3.04 | |
Dielectric Constant | 1MHz | ASTMD150 | 3.02 | |
Dissipation Factor | 60Hz | ASTMD150 | 7E-04 | |
Dissipation Factor | 1kHz | ASTMD150 | 1E-03 | |
Dissipation Factor | 1MHz | ASTMD150 | 6E-03 | |
Impact Properties | Test Condition | Test Method | Test Result | Unit |
---|
Tensile Impact Strength | | ASTMD1822 | 420 | kJ/m² |
Notched Izod Impact Strength | | ASTMD256 | 69 | J/m |
Flammability | Test Condition | Test Method | Test Result | Unit |
---|
Flame Rating | 1.5mm,ALL | UL94 | HB | |
Flame Rating | 4.5mm,NC | UL94 | V-0 | |
Glow Wire Flammability Index | 0.8mm | IEC60695-2-12 | 850 | °C |
Glow Wire Flammability Index | 1.6to6.0mm | IEC60695-2-12 | 960 | °C |
Glow Wire Ignition Temperature | 0.8mm | IEC60695-2-13 | 875 | °C |
Glow Wire Ignition Temperature | 1.6to6.0mm | IEC60695-2-13 | 850 | °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.