PBT CELANEX® 3300 CF2001 CELANESE USA
5
- Unit Price:US$ 3,930 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:30MT
- Delivery Terms:FOB
- Port of Loading :Guangzhou port, China
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Transaction Guarantee:
Supplier Information
Guangzhou Hushang Chemical Co., Ltd
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:Glass fiber reinforced|30% enhancement
- Application Areas:Automotive sector
- Color:--
- Grade:Enhanced level
Technical Data Sheet
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Rockwell hardness | ISO 2039-2 | 90 | M | |
| Impact strength of cantilever beam gap | 23℃ | ISO 180/1A | 7.5 | KJ/m |
| Charpy Notched Impact Strength | -30℃ | ISO 179/1eA | 8.5 | KJ/m |
| 23℃ | ISO 179/1eA | 8.5 | KJ/m | |
| -30℃ | ISO 179/1eU | 45 | KJ/m | |
| 23℃ | ISO 179/1eU | 46 | KJ/m | |
| bending strength | 23℃ | ISO 178 | 210 | Mpa |
| Bending modulus | 23℃ | ISO 178 | 9700 | Mpa |
| Elongation at Break | 5mm/min | ISO 527-2/1A | 2.5 | % |
| tensile strength | 5mm/min | ISO 527-2/1A | 130 | Mpa |
| Tensile modulus | 1mm/min | ISO 527-2/1A | 9200 | Mpa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL 94 | HB | ||
| Extreme Oxygen Index | ISO 4589 | 20 | % | |
| Linear coefficient of thermal expansion | Across Flow | ISO 11359-2 | 1 | E-4/℃ |
| Across Flow | ISO 11359-2 | 0.25 | E-4/℃ | |
| Vicat softening temperature | ISO 306 | 220 | °C | |
| Hot deformation temperature | 8.0Mpa | ISO 75-1/-2 | 150 | °C |
| 0.45Mpa | ISO 75-1/-2 | 225 | °C | |
| Melting temperature | ISO 11357-1 | 225 | °C | |
| Glass transition temperature | ISO 11357-1 | 60 | °C | |
| Hot deformation temperature | 1.8Mpa | ISO 75-1/-2 | 205 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 23℃,50%相对湿度 | ISO 62 | 0.2 | % |
| 23℃,Saturation | ISO 62 | 0.4 | % | |
| Shrinkage rate | Across Flow | ISO 294-4 | 0.7-0.9 | % |
| Across Flow | ISO 294-4 | 0.3-0.5 | % | |
| Melt Volume Flow Rate (MVR) | ISO 1133 | 17 | CM | |
| density | ISO 1183 | 1530 | kg/m | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | 1MHz | IEC 60250 | 4.1 | |
| 100Hz | IEC 6250 | 4.5 | ||
| Dielectric dissipation factor | 100Hz | IEC 60250 | 22 | E-4 |
| 1MHz | IEC 60250 | 160 | E-4 | |
| Volume resistivity | IEC 60093 | >1E13 | ohm.m | |
| Surface resistivity | IEC 60093 | >1E15 | Ohm | |
| Dielectric strength | IEC 60243-1 | 31 | KV/mm | |
| Compared to the Leakage Traceability Index (CTI) | IEC 60112 | 425 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.
Other Prices
| Supplier | Unit Price |
|---|---|
| Shenzhen Jufengde | US$ 3060 /MT |
| ASIAPLAS | US$ 3530 /MT |