POM Delrin® II100 NC010 DUPONT USA
278
- Unit Price:US$ 4,850 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:45.5MT
- Delivery Terms:FOB
- Port of Loading :Guangzhou port, China
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:High rigidity|High hardness|Thermal stability|high viscosity|heat-resisting
- Application Areas:Thin walled products|Fitness equipment
- Color:--
- Grade:--
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 430 | kJ/m² |
| 23°C | ISO 179/1eU | NoBreak | ||
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| Atomization | G-value(condensate) | ISO 6452 | 1E-04 | g |
| F-value(refraction) | ISO 6452 | 91 | % | |
| Burning rate | 1.00mm | ISO 3795 | 30 | mm/min |
| UL flame retardant rating | 0.8mm | UL 94 | HB | |
| 1.5mm | UL 94 | HB | ||
| 0.8mm | IEC 60695-11-10,-20 | HB | ||
| 1.5mm | IEC 60695-11-10,-20 | HB | ||
| FMVSS flammability | FMVSS302 | B | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Tensile strain | Yield | ISO 527-2 | 26 | % |
| tensile strength | Yield | ISO 527-2 | 72.0 | Mpa |
| Tensile modulus | ISO 527-2 | 3000 | Mpa | |
| Nominal tensile fracture strain | ISO 527-2 | 45 | % | |
| Tensile creep modulus | 1hr | ISO 899-1 | 2900 | Mpa |
| 1000hr | ISO 899-1 | 1600 | Mpa | |
| Bending modulus | ISO 178 | 2900 | Mpa | |
| bending strength | 3.5%Strain | ISO 178 | 79.0 | Mpa |
| Compressive stress | ISO 604 | 110 | Mpa | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | TD:-40to23°C | ISO 11359-2 | 1E-04 | cm/cm/°C |
| TD:-- | ISO 11359-2 | 1.1E-04 | cm/cm/°C | |
| MD:-40to23°C | ISO 11359-2 | 1E-04 | cm/cm/°C | |
| TD:EffectiveThermalDiffusivity | ISO 11359-2 | 1E-07 | m²/s | |
| TD:AnnealingTime-Optional | ISO 11359-2 | 30.0 | min/mm | |
| TD:AnnealingTemperature | ISO 11359-2 | 160 | °C | |
| MD:-- | ISO 11359-2 | 1.1E-04 | cm/cm/°C | |
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 160 | °C |
| 1.8MPa,Unannealed | ISO 75-2/A | 100 | °C | |
| Vicat softening temperature | -- | ISO 306/A50 | 175 | °C |
| -- | ISO 306/B50 | 160 | °C | |
| Melting temperature | ISO 11357-3 | 178 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Saturation,23°C,2.00mm | ISO 62 | 0.90 | % |
| Shrinkage rate | MD | ISO 294-4 | 2.2 | % |
| TD | ISO 294-4 | 1.8 | % | |
| Melt Volume Flow Rate (MVR) | 190°C/2.16kg | ISO 1133 | 1.90 | cm3/10min |
| melt mass-flow rate | ISO 1133 | 2.3 | g/10min | |
| SpecificHeatCapacity of Melt | 3000 | J/kg/°C | ||
| MediumDensity | 1.19 | g/cm³ | ||
| Water absorption rate | Equilibrium,23°C,2.00mm,50%RH | ISO 62 | 0.20 | % |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Relative permittivity | 100Hz | IEC 60250 | 3.90 | |
| Dielectric strength | IEC 60243-1 | 41 | KV/mm | |
| Volume resistivity | IEC 60093 | >1.0E+15 | ohms·cm | |
| Surface resistivity | IEC 60093 | 3E+13 | ohms | |
| Relative permittivity | 1MHz | IEC 60250 | 3.80 | |
| Dissipation factor | 100Hz | IEC 60250 | 1E-03 | |
| 1MHz | IEC 60250 | 5.5E-03 | ||
| Compared to the anti leakage trace index | IEC 60112 | PLC 0 | ||
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | R-Sale | ISO 2039-2 | 121 | |
| M-Sale | ISO 2039-2 | 90 | ||
| Supplementary Information | Test Condition | Test Method | Test Result | Test Unit |
| EmissionofOrganicCompounds | VDA277 | 4.00 | µgC/g | |
| Emission | VDA275 | <8.00 | mg/kg |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.