PMMA Altuglas® V825 ARKERMA KOREA
365
- Unit Price:US$ 2,558 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:10MT
- Delivery Terms:FOB
- Port of Loading :Dongguan Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:transparent|wear resistant|High temperature resistance
- Application Areas:Automotive sector
- Color:--
- Grade:Withdrawal level
Technical Data Sheet
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Water absorption rate | 24hr | 0.3 | 0.3 | % |
| melt mass-flow rate | ASTM D-1238 | 3.7 | g/10min | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | ASTM D-790 | 1.050 | Kgf/cm | |
| Bending modulus | 32.000 | Kgf/cm | ||
| Impact strength of cantilever beam gap | ASTM D-256 | 4.4 | kgf-cm/cm | |
| tensile strength | ASTM D-638 | 720 | Kgf/cm | |
| Impact strength of cantilever beam gap | ASTM D-256 | 1.2 | kgf-cm/cm | |
| Rockwell hardness | ASTM D-785 | 97 | ||
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.86kgf/cm | ASTM D-648 | 102 | °C |
| Glass transition temperature | ASTM D-3418 | 109 | °C | |
| Vicat softening temperature | ASTM D-1525 | 111 | °C | |
| Long term use temperature | 85-102 | °C | ||
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | 48hr | ASTM D-955 | 0.002-0.006 | % |
| Refractive index | ASTM D-542 | 1.49 | ||
| transparency | ASTM D-1003 | 92 | % | |
| turbidity | 2 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.