PC Makrolon® 9415 COVESTRO GERMANY
393
- Unit Price:US$ 3,545 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:15MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:enhance|Filler: Glass fiber reinforced material|10% filler by weight
- Application Areas:Fiber grade
- Color:--
- Grade:Enhanced level
Material Certification

Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Multi axis Instrumented Peak Impact Force | 23°C | ISO 6603-2 | 4000 N |
| -30°C | ISO 6603-2 | 3700 N | |
| Multi axis Instrumented Impact Energy | 23°C | ISO 6603-2 | 25.0 J |
| -30°C | ISO 6603-2 | 15.0 J | |
| Impact strength of cantilever beam gap | 23°C,CompleteBreak | ISO 7391 | 10 kJ/m² |
| Charpy Notched Impact Strength | 23°C,CompleteBreak | ISO 7391 | 10 kJ/m² |
| Impact strength of simply supported beam without notch | -60°C,CompleteBreak | ISO 179/1eU | 100 kJ/m² |
| -30°C,Complete Break | ISO 179/1eU | 120 kJ/m² | |
| 23°C,Complete Break | ISO 179/1eU | 150 kJ/m² |
| flammability | Test Condition | Test Method | Test Result |
|---|---|---|---|
| FlashIgnitionTemperature | ASTM D1929 | 470 °C | |
| Burning rate - US-FMVSS | >1.00mm | ISO 3795 | passed |
| Small flame combustion test | MethodKandF:2.00mm | DIN 53438-1,-3 | K1.F1 |
| 2.00mm | DIN 4102 | B2 | |
| Extreme Oxygen Index | ISO 4589-2 | 35 % | |
| Hot filament ignition temperature | 3.0mm | IEC 60695-2-13 | 900 °C |
| 1.5mm | IEC 60695-2-13 | 900 °C | |
| 0.75mm | IEC 60695-2-13 | 900 °C | |
| Burning wire flammability index | 3.0mm | IEC 60695-2-12 | 960 °C |
| 1.5mm | IEC 60695-2-12 | 960 °C | |
| UL flame retardant rating | 0.75mm | UL 94 | V-2 |
| 1.5mm | UL 94 | V-0 | |
| 3.0mm | UL 94 | 5VA | |
| Burning wire flammability index | 0.75mm | IEC 60695-2-12 | 960 °C |
| Needle flame test | MethodF:1.50mm | IEC 60695-11-5 | 2.0 min |
| MethodF:2.00mm | IEC 60695-11-5 | 2.0 min | |
| MethodF:3.00mm | IEC 60695-11-5 | 2.0 min | |
| MethodK:1.50mm | IEC 60695-11-5 | 1.0 min | |
| MethodK:2.00mm | IEC 60695-11-5 | 2.0 min | |
| MethodK:3.00mm | IEC 60695-11-5 | 2.0 min | |
| SelfIgnition | ASTM D1929 | 550 °C |
| mechanical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Tensile strain | Break,23°C | ISO 527-2/5 | 15 % |
| Tensile creep modulus | 1hr | ISO 899-1 | 3600 Mpa |
| Tensile modulus | 23°C | ISO 527-2/1 | 3800 Mpa |
| tensile strength | Yield,23°C | ISO 527-2/5 | 64.0 Mpa |
| Break,23°C | ISO 527-2/5 | 45.0 Mpa | |
| Tensile strain | Yield,23°C | ISO 527-2/5 | 4.4 % |
| Tensile creep modulus | 1000hr | ISO 899-1 | 2900 Mpa |
| Bending modulus | 23°C | ISO 178 | 3600 Mpa |
| bending strength | 3.5%Strain,23°C | ISO 178 | 95.0 Mpa |
| 23°C | ISO 178 | 105 Mpa | |
| Bending strain | 23°C | ISO 178 | 5.8 % |
| thermal performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Vicat softening temperature | -- | ISO 306/B120 | 146 °C |
| -- | ISO 306/B50 | 145 °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 136 °C |
| 0.45MPa,Unannealed | ISO 75-2/B | 142 °C | |
| RTI Elec | 1.5mm | UL 746 | 125 °C |
| RTI Imp | 1.5mm | UL 746 | 115 °C |
| Ball Pressure Test | 137°C | IEC 60695-10-2 | Pass |
| Linear coefficient of thermal expansion | MD:23to55°C | ISO 11359-2 | 4E-05 cm/cm/°C |
| TD:23to55°C | ISO 11359-2 | 6.5E-05 cm/cm/°C | |
| thermal conductivity | 23°C | ISO 8302 | 0.22 W/m/K |
| RTI Str | 1.5mm | UL 746 | 125 °C |
| Physical properties | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Shrinkage rate | TD | ISO 2577 | 0.40-0.60 % |
| Melt Volume Flow Rate (MVR) | 300°C/1.2kg | ISO 1133 | 6.00 cm3/10min |
| melt mass-flow rate | 300°C/1.2kg | ISO 1133 | 7.0 g/10min |
| Apparent density | ISO 60 | 0.64 g/cm³ | |
| density | 23°C | ISO 1183 | 1.27 g/cm³ |
| Shrinkage rate | MD | ISO 2577 | 0.40-0.60 % |
| TD:2.00mm3 | ISO 294-4 | 0.45 % | |
| MD:2.00mm3 | ISO 294-4 | 0.60 % | |
| Water absorption rate | Saturation,23°C | ISO 62 | 0.26 % |
| Equilibrium,23°C,50%RH | ISO 62 | 0.10 % |
| Electrical performance | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Relative permittivity | 23°C,100Hz | IEC 60250 | 3.20 |
| 23°C,1MHz | IEC 60250 | 3.20 | |
| Dissipation factor | 23°C,100Hz | IEC 60250 | 1E-03 |
| 23°C,1MHz | IEC 60250 | 9E-03 | |
| Compared to the anti leakage trace index | SolutionA | IEC 60112 | PLC 3 |
| SolutionB | IEC 60112 | PLC 4 | |
| Surface resistivity | IEC 60093 | 1E+16 ohms | |
| Volume resistivity | 23°C | IEC 60093 | 1E+16 ohms·cm |
| Dielectric strength | 23°C,1.00mm | IEC 60243-1 | 36 KV/mm |
| hardness | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Ball Pressure Test | ISO 2039-1 | 128 Mpa |
| Supplementary Information | Test Condition | Test Method | Test Result |
|---|---|---|---|
| Electrolytic corrosion | 23°C | IEC 60426 | A1 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.