Material Description
- Material Properties:high viscosity|Flame retardant|UV resistance
- Application Areas:Casters|Household appliances
- Color:--
- Grade:Injection grade
Material Certification

Technical Data Sheet
| optical performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Transmittance rate | 2.54mm | ASTM D1003 | 85 | % |
| turbidity | 2.54mm | ASTM D1003 | 1 | % |
| Refractive index | ASTM D542 | 1.586 | - | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL certification, 94V-2 flame rating | UL 94 | 1.47 | mm | |
| UL certification, 94V-0 flame rating | UL 94 | 2.99 | mm | |
| UV-light,waterexposure/immersion | UL 746C | F1 | - | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | 1.3mm/min,50mmSpan | ASTM D790 | 920 | Kgf/cm2 |
| Bending modulus | 1.3mm/min,50mmSpan | ASTM D790 | 22800 | Kgf/cm2 |
| Rockwell hardness | M-Scale | ASTM D785 | 70 | - |
| Tensile strain | TypeI,50mm/min | ASTM D638 | 90 | % |
| TypeI,50mm/min | ASTM D638 | 7 | % | |
| tensile strength | TypeI,50mm/min | ASTM D638 | 560 | Kgf/cm2 |
| TypeI,50mm/min | ASTM D638 | 630 | Kgf/cm2 | |
| Dart impact (D3029), 23 ℃ | ASTM D3029 | 1728 | cm-kgf | |
| Impact strength of cantilever beam gap | S型 | ASTM D1822 | 535 | cm-kgf/cm² |
| 23°C | ASTM D256 | 65 | cm-kgf/cm | |
| Suspended wall beam without notch impact strength | 23°C | ASTM D4812 | 326 | cm-kgf/cm |
| Taber abraser | CS-17,1kg | ASTM D1044 | 10 | mg/1000cy |
| Rockwell hardness | R-Scale | ASTM D785 | 118 | - |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Relative temperature index, Mechw/oimpact | UL 746B | 130 | °C | |
| Relative temperature index, Mechw/impact | UL 746B | 120 | °C | |
| Relative temperature index, Elec | UL 746B | 130 | °C | |
| thermal conductivity | ASTMC177 | 0.19 | W/m-°C | |
| Linear coefficient of thermal expansion | -40°C至95°C,Flow | ASTME831 | 6.84E-05 | 1/°C |
| Hot deformation temperature | 1.82MPa,6.4mm,Unannealed | ASTM D648 | 132 | °C |
| 0.45MPa,6.4mm,Unannealed | ASTM D648 | 137 | °C | |
| Vicat softening temperature | 速率B/50 | ASTM D1525 | 151 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Mold shrinkage flow, 3.2mm | SABICMethod | 0.5-0.7 | % | |
| Water absorption rate | Equilibrium,100°C | ASTM D570 | 0.58 | % |
| Equilibrium,23°C | ASTM D570 | 0.35 | % | |
| 24hr | ASTM D570 | 0.15 | % | |
| density | 比重 | ASTM D792 | 1.217 | g/cm³ |
| Specific volume | ASTM D792 | 0.83 | cm³/g | |
| density | 比重 | ASTM D792 | 1.21 | - |
| melt mass-flow rate | 300°C/1.2kgf | ASTM D1238 | 7 | g/10min |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Volume resistivity | ASTM D257 | >1.E+17 | ohm-cm | |
| Dielectric strength, in air, 3.2mm | ASTM D149 | 16.7 | KV/mm | |
| Relative permittivity, 50/60Hz | ASTM D150 | 3.01 | - | |
| Relative permittivity, 1MHz | ASTM D150 | 2.96 | - | |
| Dissipation factor, 50/60Hz | ASTM D150 | 0.0009 | - | |
| Dissipation factor, 1MHz | ASTM D150 | 0.01 | - | |
| Arc resistance, Tungsten{PLC} | ASTM D495 | PLC_7 | ||
| High voltage arc tracing rate | HVTR){PLC} | UL 746A | PLC 3 | |
| HighAmpereArcIgn,surface{PLC} | UL 746A | PLC_2 | ||
| Compared to the Leakage Traceability Index (CTI) | UL){PLC} | UL 746A | PLC_3 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.