PC LEXAN™ 141R-111 SABIC INNOVATIVE SINGAPHORE
328
- Unit Price:US$ 1,757 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:30MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
- Material Comparison:
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
For more details, please contact the supplier!
Material Description
- Material Properties:transparent|Flame retardant
- Application Areas:--
- Color:--
- Grade:Injection grade
Material Certification

Technical Data Sheet
optical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Transmittance rate | 2.54 mm | ASTM D1003 | 88 % |
impact performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Instrumented dart impact energy 23 ℃ (73 ℉) total energy | / | ASTM D3763 | 63 J |
Suspended wall beam without notch impact strength | /,23℃ | ASTM D4812 | 3204 J/m |
Impact strength of cantilever beam gap | 23℃ | ASTM D256 | 801 J/m |
mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Bending modulus | 1.3 mm/ | ASTM D790 | 2340 Mpa |
bending strength | 1.3 mm/min/,Yield | ASTM D790 | 96 Mpa |
Elongation at Break | Type I, 5 | ASTM D638 | 130 % |
elongation | Type I, 5,Yield | ASTM D638 | 7 % |
tensile strength | Type I, 5,Break | ASTM D638 | 68 Mpa |
Type I, 5,Yield | ASTM D638 | 62 Mpa |
thermal properties | Test Condition | Test Method | Test Result |
---|---|---|---|
RTI Imp | UL 746B | 130 °C | |
RTI Elec | UL 746B | 130 °C | |
RTI Imp | UL 746B | 130 °C | |
Vicat softening temperature | Rate B/50 | ASTM D1525 | 154 °C |
Physical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
melt mass-flow rate | /,300℃/1.2 kg | ASTM D1238 | 10.5 g/10min |
Shrinkage rate | flow, 3.2 | Internal | 0.5-0.7 |
Water absorption rate | 24 hours | ASTM D570 | 0.15 |
equilibriu | ASTM D570 | 0.58 | |
Bi Rong | / | ASTM D792 | 0.83 |
Water absorption rate | equilibriu | ASTM D570 | 0.35 |
hardness | Test Condition | Test Method | Test Result |
---|---|---|---|
Hardness (Rockwell R) | ASTM D 785 | 118 R | |
Hardness (Rockwell M) | ASTM D 785 | 70 M |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.