ABS D-120 GPPC TAIWAN
454
- Unit Price:US$ 2,080 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:53MT
- Delivery Terms:FOB
- Port of Loading :Kaoshiung port, China
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:high strength|dimensional stability
- Application Areas:Automotive sector|Household goods|Electrical field|Electronic field
- Color:--
- Grade:Extrusion grade
Material Certification

Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Impact strength of cantilever beam gap | 3.18mm | ASTM D256 | 440 | J/m |
| 6.35mm | ASTM D256 | 370 | J/m | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 1.6mm | UL 94 | HB | |
| 3.2mm | UL 94 | HB | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| tensile strength | 3.18mm | ASTM D638 | 42.7 | Mpa |
| Bending modulus | 3.18mm | ASTM D790 | 2210 | Mpa |
| bending strength | 3.18mm | ASTM D790 | 70.6 | Mpa |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 1.8MPa,Unannealed,12.7mm | ASTM D648 | 88.0 | °C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| density | ASTM D792 | 1.03 | g/cm³ | |
| melt mass-flow rate | 200°C/5.0kg | ASTM D1238 | 1.4 | g/10min |
| 220°C/10.0kg | ISO 1133 | 14 | g/10min | |
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | R-Scale | ASTM D785 | 102 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.