PA6 Amilan® CM1011G15 TORAY SHENZHEN
223
- Unit Price:US$ 2,572 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:46.5MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
- Material Comparison:PA6 Novamid® 1013G-15 MITSUBISHI ENGINEERING JAPAN
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
For more details, please contact the supplier!
Material Description
- Material Properties: Glass 45% reinforced|High modulus application|High impact| Glass 45% reinforced|High modulus application|High impact
- Application Areas:--
- Color:--
- Grade:Injection grade
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ASTM D-792 | 无水|1.5 | |
ASTM D-792 | 1.9%水|- | ||
Taber abraser | ASTM D-1044 | 无水|30 mg/1000次 | |
ASTM D-1044 | 1.9%水|- mg/1000次 |
Basic performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Water absorption rate | ASTM D-570 | 无水|0.9 % | |
ASTM D-570 | 1.9%水|- % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
bending strength | ASTM D-790 | 无水|16000 kg/cm2 | |
ASTM D-790 | 1.9%水|- kg/cm2 | ||
ASTM D-790 | 无水|3300 kg/cm2 | ||
ASTM D-790 | 1.9%水|- kg/cm2 | ||
tensile strength | ASTM D-638 | 无水|2000 kg/cm2 | |
ASTM D-638 | 1.9%水|1300 kg/cm2 | ||
ASTM D-638 | 无水|1200 kg/cm2 | ||
ASTM D-638 | 1.9%水|- kg/cm2 | ||
ASTM D-638 | 无水|2900 kg/cm2 | ||
ASTM D-638 | 1.9%水|- kg/cm2 | ||
compressive strength | ASTM D-695 | 无水|1900 kg/cm2 | |
ASTM D-695 | 1.9%水|- kg/cm2 | ||
ASTM D-695 | 无水|1000 kg/cm2 | ||
ASTM D-695 | 1.9%水|- kg/cm2 | ||
ASTM D-695 | 无水|2600 kg/cm2 | ||
ASTM D-695 | 1.9%水|- kg/cm2 | ||
Impact strength of cantilever beam gap | ASTM D-256 | 1.9%水|120 kg·cm/cm | |
Flexural modulus | ASTM D-790 | 无水|122000 kg/cm2 | |
ASTM D-790 | 1.9%水|72000 kg/cm2 | ||
ASTM D-790 | 无水|63000 kg/cm2 | ||
ASTM D-790 | 1.9%水|45000 kg/cm2 | ||
ASTM D-790 | 无水|140000 kg/cm2 | ||
ASTM D-790 | 1.9%水|120000 kg/cm2 | ||
Rockwell hardness | ASTM D-785 | 无水|95 M-标度 | |
ASTM D-785 | 1.9%水|- M-标度 | ||
ASTM D-785 | 无水|121 R-标度 | ||
elongation at break | ASTM D-638 | 无水|5 % | |
ASTM D-638 | 1.9%水|5 % | ||
Impact strength of cantilever beam gap | ASTM D-256 | 无水|12.5 kg·cm/cm | |
ASTM D-256 | 1.9%水|15 kg·cm/cm | ||
ASTM D-256 | 无水|12.5 kg·cm/cm2 | ||
ASTM D-256 | 1.9%水|15 kg·cm/cm2 | ||
ASTM D-256 | 无水|15 kg·cm/cm | ||
ASTM D-256 | 1.9%水|20 kg·cm/cm | ||
ASTM D-256 | 无水|98 kg·cm/cm | ||
shearing strength | ASTM D-732 | 无水|940 kg/cm2 | |
ASTM D-732 | 1.9%水|750 kg/cm2 | ||
Rockwell hardness | ASTM D-785 | 1.9%水|- R-标度 | |
bending strength | ASTM D-790 | 无水|2900 kg/cm2 | |
ASTM D-790 | 1.9%水|1850 kg/cm2 |
Other performance | Test Condition | Test Method | Test Result |
---|---|---|---|
filler content | 无水|45 wt% | ||
1.9%水|- wt% |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Dissipation Factor | ASTM D-150 | 无水|0.02 | |
ASTM D-150 | 1.9%水|0.06 | ||
dielectric strength | ASTM D-149 | 无水|19 KV/mm | |
ASTM D-149 | 1.9%水|15 KV/mm | ||
dielectric constant | ASTM D-150 | 无水|4.2 | |
ASTM D-150 | 1.9%水|4.5 | ||
ASTM D-150 | 无水|4.9 | ||
ASTM D-150 | 1.9%水|7.4 | ||
Volume resistivity | ASTM D-257 | 无水|1015 Ω.cm | |
ASTM D-257 | 1.9%水|1012 Ω.cm | ||
Dissipation Factor | ASTM D-150 | 无水|0.03 | |
ASTM D-150 | 1.9%水|0.16 | ||
arc resistance | ASTM D-495 | 无水|104 S | |
ASTM D-495 | 1.9%水|119 S |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Heat distortion temperature | ASTM D-648 | 无水|225 °C | |
ASTM D-648 | 1.9%水|- °C | ||
melting temperature | 差示扫描测热计DSC | 225 °C | |
specific heat | 无水|0.31 Cal/g·℃ | ||
1.9%水|- Cal/g·℃ | |||
Linear coefficient of thermal expansion | ASTM D-696 | 无水|2-3 ×10-5cm/cm/℃ | |
ASTM D-696 | 1.9%水|- ×10-5cm/cm/℃ | ||
UL-94 flame retardant grade | UL 94 | 无水|HB | |
UL 94 | 1.9%水|- |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.
Contact Us
Get App
Top