POM TENAC™-C 4520 ASAHIKASEI ZHANGJIAGANG
578
- Unit Price:US$ 2,230 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:238MT
- Delivery Terms:FOB
- Port of Loading :Lianyungang port, China
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
- Material Comparison:
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:currency|Weather resistance|High temperature resistance|wear resistant| Balanced fluidity and mechanical properties
- Application Areas:Fitness equipment|Automotive sector|Industrial machinery|Engine parts|Cam|hose connector|Clip|switch|Mechanical components of audio/video equipment
- Color:--
- Grade:Injection grade
Technical Data Sheet
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| melt mass-flow rate | 9 | g/10min | ||
| Water absorption rate | ASTM D-570 | 0.2 | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| elongation | Break | 55 | % | |
| Rockwell hardness | ASTM D-785 | 80 | M-scale | |
| tensile strength | Break | ASTM D-638 | 66 | Mpa |
| Tensile modulus | ASTM D-790 | 2800 | Mpa | |
| Rockwell hardness | ASTM D-785 | 115 | R scale | |
| bending strength | ASTM D-790 | 88 | Mpa | |
| Impact strength of cantilever beam gap | ASTM D-256 | 7 | J/m | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | UL 94 | HB | ||
| Hot deformation temperature | 0.45MPa | ASTM D-648 | 156 | °C |
| 1.8MPa | ASTM D-648 | 100 | °C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Wear factor | ASTM D-1044 | 14 | mg/1000cycles | |
| density | ASTM D-792 | 1.41 | ||
| Shrinkage rate | 旭化成方法 | 1.6-2.0 | % |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.