PBT VALOX™  4012G SABIC INNOVATIVE US

205
  • Unit Price:US$ 3,844 /MT
  • Packaging Specification:
    25 KG/PKG
  • Packaging Material:
    Paper bag
  • Supply Quantity:
    25.8MT
  • Delivery Terms:
    FOB
  • Port of Loading :
    China Main Port
  • Accepted Payment Methods:
    T/T
  • Shipping:
    Negotiate supplier for shipping details

Supplier Information

ASIA PLASTIC EXCHANGE LIMITED

+86 755 ********View
serv********View

For more details, please contact the supplier!

Material Description

  • Material Properties:DuctilityFast forming cycle
  • Application Areas:Laptop case
  • Color:--
  • Grade:Enhanced level

Technical Data Sheet Compare

hardnessTest ConditionTest MethodTest Result
ball-indentation hardnessH358/30ISO 2039-1117 Mpa
thermal performanceTest ConditionTest MethodTest Result
Heat Deflection Temperature0.45MPa,Unannealed,100mmSpanISO 75-2/Be215 °C
Heat Deflection Temperature1.8MPa,未退火,3.20mmASTM D648175 °C
Heat Deflection Temperature1.8MPa,Unannealed,100mmSpanISO 75-2/Ae170 °C
vicatASTM D152511205 °C
vicat--ISO 306/B50205 °C
vicat--ISO 306/B120208 °C
ball-indentation hardness125°CIEC 60695-10-2Pass
Linear coefficient of thermal expansionMD:-40到40°CASTME8316E-05 cm/cm/°C
Linear coefficient of thermal expansionMD:23到80°CISO 11359-26E-05 cm/cm/°C
Linear coefficient of thermal expansionTD:-40到40°CASTME8318E-05 cm/cm/°C
Linear coefficient of thermal expansionTD:23到150°CISO 11359-28.5E-05 cm/cm/°C
Linear coefficient of thermal expansionTD:23到80°CISO 11359-28E-05 cm/cm/°C
flammabilityTest ConditionTest MethodTest Result
UL flame retardant rating1.6mmUL 94HB
Burning wire flammability index1.0mmIEC 60695-2-12750 °C
Impact resistanceTest ConditionTest MethodTest Result
Dart impact23°C,TotalEnergyASTM D37634.00 J
Impact strength of cantilever beam gap23°CISO 180/1A6.0 kJ/m²
Suspended wall beam without notch impact strength-30°CISO 180/1U37 kJ/m²
Suspended wall beam without notch impact strength23°CISO 180/1U37 kJ/m²
Charpy Notched Impact Strength-30°CISO 179/1eA6.0 kJ/m²
Charpy Notched Impact Strength23°CISO 179/1eA7.0 kJ/m²
Impact strength of simply supported beam without notch-30°CISO 179/1eU45 kJ/m²
Impact strength of simply supported beam without notch23°CISO 179/1eU45 kJ/m²
Impact strength of cantilever beam gap-30°CASTM D25674 J/m
Impact strength of cantilever beam gap23°CASTM D25674 J/m
Impact strength of cantilever beam gap-30°CISO 180/1A6.0 kJ/m²
Electrical performanceTest ConditionTest MethodTest Result
Compared to the Leakage Tracking Index (CTI)--IEC 60112 V
Compared to the Leakage Tracking Index (CTI)解决方案BIEC 60112 V
dielectric strength1.60mm,在油中IEC 60243-125 KV/mm
dielectric strength3.20mm,在油中IEC 60243-117 KV/mm
relative permittivity50HzIEC 602503.10
relative permittivity60HzIEC 602503.10
relative permittivity1MHzIEC 602503.00
Dissipation Factor50HzIEC 602501E-03
Dissipation Factor60HzIEC 602501E-03
Dissipation Factor1MHzIEC 602500.014
Surface ResistivityIEC 60093>1.0E+15 ohms
volume resistivityIEC 60093>1.0E+15 ohms·cm
dielectric strength0.800mm,在油中IEC 60243-130 KV/mm
Physical propertiesTest ConditionTest MethodTest Result
densityASTM D7921.39 g/cm³
densityISO 11831.39 g/cm³
melt mass-flow rate250°C/1.2kgASTM D123810 g/10min
Melt volume flow rate250°C/1.2kgISO 11339.00 cm3/10min
shrinkage rateMD:--2内部方法0.60-0.90 %
shrinkage rateMD:3.20mm内部方法0.60-1.6 %
Water absorption rate平衡,23°C,50%RHISO 620.070 %
shrinkage rateTD2内部方法0.70-1.0 %
Water absorption rate饱和,23°CISO 620.20 %
mechanical propertiesTest ConditionTest MethodTest Result
flexural modulusISO 1783500 Mpa
bending strengthISO 178110 Mpa
bending strengthYield,50.0mmSpanASTM D790110 Mpa
Tensile modulusASTM D6384600 Mpa
Tensile modulusISO 527-2/14500 Mpa
tensile strength屈服ASTM D63875.0 Mpa
tensile strength屈服ISO 527-2/572.0 Mpa
tensile strengthBreakASTM D63875.0 Mpa
tensile strength断裂ISO 527-2/572.0 Mpa
elongation屈服ASTM D6383.0 %
Tensile strain屈服ISO 527-2/54.0 %
elongation断裂ASTM D6383.0 %
Tensile strain断裂ISO 527-2/54.0 %
flexural modulus50.0mmSpanASTM D7903940 Mpa
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.

Contact Us

Get App

Top