PA66 Leona™ CR301 ASAHI JAPAN
392
- Unit Price:US$ 4,094 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:67.3MT
- Delivery Terms:FOB
- Port of Loading :Guangzhou port, China
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:dimensional stability |Conductive
- Application Areas:Electrical components|Electrical field|Electronic field|Switch panel|Industrial applications
- Color:--
- Grade:Injection grade
Technical Data Sheet
| other | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| purpose | 自动车电装部件 | |||
| characteristic | 电气特性 | |||
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of simply supported beam without notch | ISO 179 | 51 | kJ/m² | |
| flammability | Test Condition | Test Method | Test Result | Test Unit |
| UL flame retardant rating | 0.75 mm | UL 94 | HB | |
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 湿 | 1.5 | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | ASTM D790/ISO 178 | 147(MPa) | kg·cm/cm(J/M)ft·lb/in | |
| Bending modulus | ASTM D790/ISO 178 | 5880(MPa) | kg·cm/cm(J/M)ft·lb/in | |
| Rockwell hardness | ASTM D785 | M85 | ||
| Elongation at Break | 干(湿) | ASTM D-638 | 3(3.5) | % |
| bending strength | 干(湿) | ASTM D-790 | 147(93) | Mpa |
| tensile strength | 干(湿) | ASTM D-638 | 88(64) | Mpa |
| flexural coefficient | 干(湿) | ASTM D-790 | 5.9(2.9) | GPa |
| Rockwell hardness | 干(湿) | ASTM D-785 | 85(-) | M Scale |
| Impact strength of cantilever beam gap | 干(湿) | ASTM D-256 | 34(39) | J/m |
| Tensile modulus | 23°C | ISO 527-2 | 7000 | Mpa |
| tensile strength | Break, 23°C | ISO 527-2 | 85.0 | Mpa |
| -- | ASTM D638 | 88.0 | Mpa | |
| elongation | Break | ASTM D638 | 3.0 | % |
| Break, 23°C | ISO 527-2 | 2.0 | % | |
| Bending modulus | -- | ASTM D790 | 5900 | Mpa |
| 23°C | ISO 178 | 7400 | Mpa | |
| bending strength | -- | ASTM D790 | 147 | Mpa |
| 23°C | ISO 178 | 140 | Mpa | |
| Taber abraser | 1000 Cycles | ASTM D1044 | -- | mg |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | ASTM D696/ISO 11359 | 4 | mm/mm.℃ | |
| Hot deformation temperature | HDT | ASTM D648/ISO 75 | 191 | ℃(℉) |
| Combustibility (rate) | UL 94 | HB | ||
| Hot deformation temperature | 1.82MPa,干 | ASTM D-648 | 191(250) | °C |
| Linear coefficient of thermal expansion | 干 | ASTM D-696 | 4 | ×10-5/K |
| Hot deformation temperature | 0.45 MPa, Unannealed | ASTM D648 | 250 | °C |
| 0.45 MPa, Unannealed | ISO 75-2/B | 249 | °C | |
| 1.8 MPa, Unannealed | ASTM D648 | 191 | °C | |
| 1.8 MPa, Unannealed | ISO 75-2/A | 188 | °C | |
| Linear coefficient of thermal expansion | Flow | ASTM D696 | 4.0E-5 | cm/cm/°C |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | Saturation, 23°C | -- | % | |
| Equilibrium, 23°C, 50% RH | ISO 62 | -- | % | |
| Shrinkage rate | Flow | Internal Method | 0.50 - 1.3 | % |
| Water absorption rate | ASTM D570/ISO 62 | 1.5 | % | |
| Shrinkage rate | ASTM D955 | 0.5-1.3 | % | |
| density | ASTM D792/ISO 1183 | 1.48 | ||
| Wear factor | 湿 | ASTM D-1044 | 8 | ×10-6kg/1000times |
| Shrinkage rate | 干 | 旭化成方法 | 0.5-1.3 | % |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Arc resistance | ASTM D495/IEC 60112 | 150 | ||
| hardness | Test Condition | Test Method | Test Result | Test Unit |
| Rockwell hardness | M-Scale | ASTM D785 | 85 | |
| M -Sale | ISO 2039-2 | 85 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.