Material Description
- Material Properties:Low viscosity
- Application Areas:Industrial applications|Electrical field|Electronic field|Automotive sector|currency|currency
- Color:--
- Grade:Injection grade
Material Certification

Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Shrinkage rate | ISO 294-4 | 0.70 % | |
ISO 2577 | 0.50-0.70 % | ||
melt mass-flow rate | ISO 1133 | 20 g/10min | |
Melt volume flow rate | ISO 1133 | 19.0 cm3/10min | |
Shrinkage rate | ISO 2577 | 0.50-0.70 % | |
Apparent density | ISO 60 | 0.66 g/cm³ | |
density | ISO 1183 | 1.20 g/cm³ | |
Water absorption rate | ISO 62 | 0.12 % | |
Shrinkage rate | ISO 294-4 | 0.65 % | |
Water absorption rate | ISO 62 | 0.30 % |
hardness | Test Condition | Test Method | Test Result |
---|---|---|---|
ball-indentation hardness | ISO 2039-1 | 115 Mpa |
optical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
refractive index | ISO 489 | 1.585 | |
transmissivity | ISO 13468-2 | 89.0 % | |
ISO 13468-2 | 89.0 % | ||
ISO 13468-2 | 88.0 % | ||
ISO 13468-2 | 87.0 % | ||
Haze ratio | ISO 14782 | <0.80 % |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
needle flame test | IEC 60695-11-5 | 1.0 min | |
IEC 60695-11-5 | 2.0 min | ||
IEC 60695-11-5 | 2.0 min | ||
IEC 60695-11-5 | 0.1 min | ||
IEC 60695-11-5 | 0.1 min | ||
IEC 60695-11-5 | 0.2 min | ||
SelfIgnitionTemperature | ASTM D1929 | 550 °C | |
UL flame retardant rating | UL 94 | HB | |
UL 94 | V-2 | ||
UL 94 | V-2 | ||
Burning wire flammability index | IEC 60695-2-12 | 850 °C | |
IEC 60695-2-12 | 930 °C | ||
Hot filament ignition temperature | IEC 60695-2-13 | 875 °C | |
Burning wire flammability index | IEC 60695-2-12 | 875 °C | |
Hot filament ignition temperature | IEC 60695-2-13 | 875 °C | |
IEC 60695-2-13 | 875 °C | ||
IEC 60695-2-13 | 875 °C | ||
Limiting Oxygen Index | ISO 4589-2 | 27 % | |
Burning rate - US-FMVSS | ISO 3795 | passed | |
ApplicationofFlamefromSmallBurner-Method | DIN 53438-1,-3 | K1.F1 | |
FlashIgnitionTemperature | ASTM D1929 | 480 °C |
Supplementary Information | Test Condition | Test Method | Test Result |
---|---|---|---|
electrolytic corrosion | IEC 60426 | A1 |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of cantilever beam gap | ISO 7391 | 15 kJ/m² | |
Impact strength of simply supported beam without notch | ISO 179/1eU | NoBreak | |
ISO 179/1eU | NoBreak | ||
ISO 179/1eU | NoBreak | ||
Charpy Notched Impact Strength | ISO 7391 | 65 kJ/m² | |
ISO 7391 | 14 kJ/m² | ||
Impact strength of cantilever beam gap | ISO 7391 | 65 kJ/m² | |
Multi axis Instrumented Impact Energy | ISO 6603-2 | 65.0 J | |
ISO 6603-2 | 55.0 J | ||
Multi axis Instrumented Peak Impact Force | ISO 6603-2 | 6000 N | |
ISO 6603-2 | 5100 N |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Bending Strain | ISO 178 | 7.1 % | |
bending strength | ISO 178 | 97.0 Mpa | |
Flexural modulus | ISO 178 | 2350 Mpa | |
bending strength | ISO 178 | 73.0 Mpa | |
Tensile creep modulus | ISO 899-1 | 1900 Mpa | |
ISO 899-1 | 2200 Mpa | ||
Tensile strain | ISO 527-2/50 | 6.0 % | |
ISO 527-2/50 | 130 % | ||
Nominal tensile fracture strain | ISO 527-2/50 | >50 % | |
tensile strength | ISO 527-2/50 | 65.0 Mpa | |
ISO 527-2/50 | 65.0 Mpa | ||
Tensile modulus | ISO 527-2/1 | 2400 Mpa |
film | Test Condition | Test Method | Test Result |
---|---|---|---|
GasPermeation | ISO 2556 | 700 cm³/m²/bar/24hr | |
ISO 2556 | 3150 cm³/m²/bar/24hr | ||
ISO 2556 | 130 cm³/m²/bar/24hr | ||
ISO 2556 | 630 cm³/m²/bar/24hr | ||
ISO 2556 | 4000 cm³/m²/bar/24hr | ||
ISO 2556 | 18900 cm³/m²/bar/24hr | ||
Water Vapor Transmission Rate | ISO 15106-1 | 15 g/m²/24hr |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
relative permittivity | IEC 60250 | 3.10 | |
IEC 60250 | 3.00 | ||
Dissipation Factor | IEC 60250 | 5E-04 | |
IEC 60250 | 9E-03 | ||
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | V | |
IEC 60112 | V | ||
Surface Resistivity | IEC 60093 | 1E+16 ohms | |
Volume resistivity | IEC 60093 | 1E+16 ohms·cm | |
dielectric strength | IEC 60243-1 | 34 KV/mm |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
vicat | ISO 306/B120 | 146 °C | |
Heat distortion temperature | ISO 75-2/B | 137 °C | |
ISO 75-2/A | 124 °C | ||
Glass Transition Temperature | ISO 11357-2 | 144 °C | |
vicat | ISO 306/B50 | 145 °C | |
ball-indentation hardness | IEC 60695-10-2 | Pass | |
Linear coefficient of thermal expansion | ISO 11359-2 | 6.5E-05 cm/cm/°C | |
ISO 11359-2 | 6.5E-05 cm/cm/°C | ||
thermal conductivity | ISO 8302 | 0.20 W/m/K | |
RTI Elec | UL 746 | 125 °C | |
RTI Imp | UL 746 | 115 °C | |
RTI Str | UL 746 | 125 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.