
PC PANLITE® L-1250Y JIAXING TEIJIN
559
- Unit Price:US$ 2,050 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Plastic bag
- Supply Quantity:32MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
- Material Comparison:
Transaction Guarantee:
Supplier Information
Dongguan Yihan Plastic Raw Material Co., Ltd.
+86 1371********View
For more details, please contact the supplier!
Material Description
- Material Properties:transparent|Medium viscosity|High mobility
- Application Areas:Industrial components|Household appliances|Mechanical components|Casters|Labor protection equipment|Nursing supplies
- Color:--
- Grade:Injection grade
Material Certification
Technical Data Sheet
| optical performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Transmittance rate | ASTM D1003/ISO 13468 | 88 | % | |
| Refractive index | ASTM D542/ISO 489 | 1.585 | ||
| other | Test Condition | Test Method | Test Result | Test Unit |
| characteristic | 吹塑成型 .对流动性要求较高的薄壁制品、电器、电子元件、机械零件、劳保、医疗用品、照明器具及灯罩、餐具、容器。 | |||
| machinability | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | Flow(Across Flow) | ASTM D-955 | 0.5-0.7 | % |
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 24hr,in 23℃ | ASTM D-570 | 0.20 | % |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| compressive strength | ASTM D-695 | 76(770) | MPa(Kgf/cm | |
| bending strength | ASTM D-790 | 90(915) | MPa(Kgf/cm | |
| Tensile modulus | ASTM D-638 | 2120(21600) | MPa(Kgf/cm | |
| tensile strength | Break点,- | ASTM D-638 | 81(830) | MPa(Kgf/cm |
| Yield点,- | ASTM D-638 | 61(620) | MPa(Kgf/cm | |
| Elongation at Break | Yield点,- | ASTM D-638 | 6 | - |
| Rockwell hardness | ASTM D-785 | 77 | M标度 | |
| Impact strength of cantilever beam gap | 艾氏、带Notched厚度3.2mm | ASTM D-256 | 880(90) | j/m(kgf.cm/cm) |
| 艾氏、带Notched厚度6.4mm | ASTM D-256 | 140(14) | j/m(kgf.cm/cm) | |
| Charpy Notched Impact Strength | ASTM D256/ISO 179 | 140(14) | kg·cm/cm(J/M)ft·lb/in | |
| Elongation at Break | Break点,- | ASTM D-638 | 140 | - |
| Bending modulus | ASTM D-790 | 2230(22700) | MPa(Kgf/cm | |
| Tensile modulus | ASTM D638/ISO 527 | 2120(21600) | kg/cm²(MPa)[Lb/in²] | |
| tensile strength | ASTM D638/ISO 527 | 61(620)屈服 81(830)断裂 | kg/cm²(MPa)[Lb/in²] | |
| elongation | ASTM D638/ISO 527 | 6 | % | |
| Rockwell hardness | ASTM D785 | M-77 | ||
| Bending modulus | ASTM D790/ISO 178 | 2230(22700) | kg/cm²(MPa)[Lb/in²] | |
| bending strength | ASTM D790/ISO 178 | 90(915) | kg/cm²(MPa)[Lb/in²] | |
| Elongation at Break | ASTM D638/ISO 527 | 140 | % | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 负荷1.813MPa(18.6kgf/cm) | ASTM D-648 | 143 | °C |
| Temperature index | 非冲击式,厚度1.47mm | UL 746B | 125 | °C |
| 冲击式,厚度1.47mm | UL 746B | 115 | °C | |
| 电学式,厚度1.47mm | UL 746B | 125 | °C | |
| Hot deformation temperature | 负荷0.451MPa(4.6kgf/cm) | ASTM D-648 | 143 | °C |
| Linear coefficient of thermal expansion | Flow(Across Flow) | ASTM D-696 | 7 | |
| ASTM D696/ISO 11359 | 7X10^-5 | mm/mm.℃ | ||
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Refractive index | ASTM D-542 | 1.585 | ||
| Transmittance rate | 厚度3mm | ASTM D-1003 | 88 | % |
| density | ASTM D792/ISO 1183 | 1.2 | ||
| Water absorption rate | ASTM D570/ISO 62 | 0.2 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Arc resistance | ASTM D-495 | 110 | secc | |
| Compared to the anti leakage trace index | CTI | IEC 112 | PLC 2 | |
| Dielectric constant | 60Hz(10 | ASTM D-150 | 2.95(2.9) | |
| Dielectric strength | 快速加压值厚度1.6mm | ASTM D-149 | 30 | KV/mm |
| Volume resistivity | ASTM D-257 | 3 | ||
| Arc resistance | ASTM D495/IEC 60112 | 110 | ||
| Volume resistivity | ASTM D257/IEC 60093 | 3 | Ω.cm | |
| Dielectric loss | 60Hz(10,Tangent | ASTM D-150 | 0.0004(0.009) |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.