PA66 1300G W11 ZHUHAI TOYOCOLOR
434
- Unit Price:US$ 3,240 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:95MT
- Delivery Terms:FOB
- Port of Loading :Zhuhai port, China
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:--
- Application Areas:--
- Color:--
- Grade:--
Technical Data Sheet
| Other performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Extreme Oxygen Index | 干 | ASTM D-2863 | 26 | % |
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
| Water absorption rate | 湿 | 2.2 | % | |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| bending strength | 干(湿) | ASTM D-790 | 128(59) | Mpa |
| Impact strength of cantilever beam gap | 干(湿) | ASTM D-256 | 39(108) | J/m |
| flexural coefficient | 干(湿) | ASTM D-790 | 3.0(1.3) | GPa |
| tensile strength | 干(湿) | ASTM D-638 | 88(67) | Mpa |
| Elongation at Break | 干(湿) | ASTM D-638 | 35(200) | % |
| Rockwell hardness | 干(湿) | ASTM D-785 | 85(60) | M Scale |
| 干(湿) | ASTM D-785 | 120(110) | R scale | |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| specific heat | 干 | 1670 | J/(kg.k) | |
| Hot deformation temperature | 1.82MPa,干 | ASTM D-648 | 75 | °C |
| 0.46MPa,干 | ASTM D-648 | 240 | °C | |
| Linear coefficient of thermal expansion | 干 | ASTM D-696 | 8 | |
| thermal conductivity | 干 | 0.2 | W/(m.K) | |
| UL flame retardant rating | 干 | UL 94 | V-2 | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Shrinkage rate | 干 | 旭化成方法 | 0.9-1.6 | % |
| Wear factor | 湿 | ASTM D-1044 | 6 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.