PC LNP™ STAT-KON™ DC-1003 BK SABIC INNOVATIVE US
219
- Unit Price:US$ 4,334 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:21MT
- Delivery Terms:FOB
- Port of Loading :Guangzhou port, China
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:Easy to form|Easy to demould|Filler: Carbon fiber reinforced material
- Application Areas:Plastic bag|Electronic and Electrical Applications
- Color:--
- Grade:Injection grade
Technical Data Sheet
| impact performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| 23°C | ASTM D256 | 74 | J/m | |
| ISO 180/1A | 6.4 | kJ/m² | ||
| ASTM D4812 | 490 | J/m | ||
| ISO 180/1U | 33 | kJ/m² | ||
| 23°C,EnergyatPeakLoad | ASTM D3763 | 15.5 | J | |
| 23°C | ASTM D256 | 74 | J/m | |
| ISO 180/1A | 6.4 | kJ/m² | ||
| ASTM D4812 | 490 | J/m | ||
| ISO 180/1U | 33 | kJ/m² | ||
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| crack | ASTM D638 | 2.1 | % | |
| ISO 527-2 | 2.0 | % | ||
| --1 | ASTM D638 | 8780 | Mpa | |
| crack | ASTM D638 | 110 | Mpa | |
| ISO 527-2 | 109 | Mpa | ||
| ASTM D638 | 2.1 | % | ||
| ISO 527-2 | 2.0 | % | ||
| --1 | ASTM D638 | 8780 | Mpa | |
| crack | ASTM D638 | 110 | Mpa | |
| ISO 527-2 | 109 | Mpa | ||
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| 0.45MPa, unannealed, 3.20mm | ASTM D648 | 145 | °C | |
| 1.8MPa, unannealed, 3.20mm | ASTM D648 | 137 | °C | |
| 1.8MPa, unannealed, 64.0mm span of | ISO 75-2/Af | 146 | °C | |
| Linear coefficient of thermal expansion | MD:-40to40°C | ASTME831 | 1.8E-05 | cm/cm/°C |
| TD:-40to40°C | ASTME831 | 5E-05 | cm/cm/°C | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Flow: 24 hours | 24hr | ASTM D955 | 0.040to0.10 | % |
| Lateral flow: 24 hours | Across Flow, 24hr | ASTM D955 | 0.30to0.40 | % |
| Vertical flow direction: 24 hours | Across Flow, 24hr | ISO 294-4 | 0.32to0.41 | % |
| Flow direction: 24 hours | Flow, 24hr | ISO 294-4 | 0.040to0.13 | % |
| Water absorption rate | 24hr,50%RH | ASTM D570 | 0.16 | % |
| density | ISO 1183 | 1.24 | g/cm³ | |
| Flow: 24 hours | 24hr | ASTM D955 | 0.040to0.10 | % |
| Lateral flow: 24 hours | Across Flow, 24hr | ASTM D955 | 0.30to0.40 | % |
| Vertical flow direction: 24 hours | Across Flow, 24hr | ISO 294-4 | 0.32to0.41 | % |
| Flow direction: 24 hours | Flow, 24hr | ISO 294-4 | 0.040to0.13 | % |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Surface resistivity | ASTM D257 | 10-1.0E+5 | ohms | |
| ASTM D257 | 10-1.0E+5 | ohms |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.