physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
Shrinkage rate | ISO 294-4 | 0.90 % | |
ISO 294-4 | 0.40 % | ||
Water absorption rate | ISO 62 | 0.50 % | |
ISO 62 | 1.2 % |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | UL 94 | HB | |
UL 94 | HB | ||
UL 94 | HB | ||
Burning wire flammability index | IEC 60695-2-12 | 675 °C | |
IEC 60695-2-12 | 675 °C | ||
IEC 60695-2-12 | 960 °C | ||
Hot filament ignition temperature | IEC 60695-2-13 | 700 °C | |
IEC 60695-2-13 | 700 °C | ||
IEC 60695-2-13 | 750 °C |
Supplementary Information | Test Condition | Test Method | Test Result |
---|---|---|---|
Automotive Materials | FMVSS302 | + |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Tensile modulus | ISO 527-2 | 16800 Mpa | |
tensile strength | ISO 527-2 | 240 Mpa | |
Tensile strain | ISO 527-2 | 2.5 % | |
Flexural modulus | ISO 178 | 16000 Mpa | |
bending strength | ISO 178 | 350 Mpa | |
Poisson's ratio | ISO 527-2 | 0.40 |
Impact resistance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of simply supported beam without notch | ISO 179/1eU | 91 kJ/m² | |
ISO 179/1eU | 95 kJ/m² |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | V | |
High arc combustion index (HAI) | UL 746 | PLC 0 | |
UL 746 | PLC 0 | ||
UL 746 | PLC 0 | ||
High Voltage Arc Traceability Rate (HVTR) | UL 746 | PLC 1 | |
Hot wire ignition (HWI) | UL 746 | PLC 4 | |
UL 746 | PLC 3 | ||
UL 746 | PLC 4 | ||
Volume resistivity | IEC 60093 | 1E+12 ohms·cm | |
dielectric strength | IEC 60243 | 20 KV/mm | |
arc resistance | ASTM D495 | PLC 5 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
RTI Elec | UL 746 | 140 °C | |
RTI Imp | UL 746 | 130 °C | |
UL 746 | 130 °C | ||
UL 746 | 130 °C | ||
RTI Str | UL 746 | 140 °C | |
UL 746 | 140 °C | ||
UL 746 | 140 °C | ||
Heat distortion temperature | ISO 75-2/B | 260 °C | |
ISO 75-2/A | 255 °C | ||
melting temperature | ISO 11357-3 | 260 °C | |
Linear coefficient of thermal expansion | ISO 11359-2 | 1.2E-05 cm/cm/°C | |
ISO 11359-2 | 1E-04 cm/cm/°C | ||
RTI Elec | UL 746 | 140 °C | |
UL 746 | 140 °C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.