PBT Toraycon® 1101G-X54-NC TORAY JAPAN
400
- Unit Price:US$ 3,240 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:22.8MT
- Delivery Terms:FOB
- Port of Loading :Guangzhou port, China
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:High impact resistance|Fast forming cycle|Flame retardant|Glass fiber reinforced
- Application Areas:Electrical field|Electronic field|Automotive sector
- Color:--
- Grade:Enhanced level
Technical Data Sheet
| Basic Performance | Test Condition | Test Method | Test Result | Test Unit |
|---|---|---|---|---|
| Water absorption rate | 23℃·24hr | ASTM D-570 | 0.07 | % |
| mechanical properties | Test Condition | Test Method | Test Result | Test Unit |
| Impact strength of cantilever beam gap | Notched,23℃,1/8时宽 | ASTM D-256 | 16 | kg·cm/cm |
| Unnotched,23℃,1/8时宽 | ASTM D-256 | 60 | kg·cm/cm | |
| Bending modulus | 23℃ | ASTM D-790 | 72 | kg/cm |
| Rockwell hardness | 23℃ | ASTM D-785 | 89 | M标度 |
| Elongation at Break | 23℃ | ASTM D-638 | 5 | % |
| tensile strength | 23℃ | ASTM D-638 | 1200 | kg/cm |
| bending strength | 23℃ | ASTM D-790 | 1700 | kg/cm |
| thermal performance | Test Condition | Test Method | Test Result | Test Unit |
| Linear coefficient of thermal expansion | ASTM D-696 | 2.5 | cm/cm℃×10 | |
| Physical properties | Test Condition | Test Method | Test Result | Test Unit |
| Hot deformation temperature | 18.6kg.cm | ASTM D-648 | 210 | °C |
| 4.6kg/cm | ASTM D-648 | 220 | °C | |
| Shrinkage rate | 80×80×3板材 | 0.4-1.0 | % | |
| Electrical performance | Test Condition | Test Method | Test Result | Test Unit |
| Dielectric strength | 短时·23℃·1/8时 | ASTM D-149 | 27(18) | KV/mm |
| Arc resistance | ASTM D-495 | 131 | 秒 | |
| Volume resistivity | ASTM D-257 | 7.5(2.2) | cm×10 |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.