- Material Properties:Aging resistance|Thermal stability
- Application Areas:Automotive sector
- Color:--
- Grade:Weather resistant grade
Material Certification

Technical Data Sheet
mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of simply supported beam without notch | 23 ℃ | ISO 179/1eU | 80 kJ/m² |
-30℃ | ISO 179/1eU | 60 kJ/m² | |
Charpy Notched Impact Strength | 23 ℃ | ISO 179/1eA | 13 kJ/m² |
-30℃ | ISO 179/1eA | 11 kJ/m² | |
-40 ℃ | ISO 179/1eA | 12 kJ/m² | |
Bending modulus | ISO 178 | 8200 Mpa | |
Tensile modulus | ISO 527 | 9500 Mpa | |
Fracture strain | ISO 527 | 3 % | |
Fracture stress | ISO 527 | 168 Mpa |
thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Linear coefficient of thermal expansion | Normal | ISO 11359-1/-2 | 0.83 E-4/C |
Melting temperature | 10°C/min | ISO 11357-1/-3 | 218 °C |
Hot deformation temperature | 1.80MPa | ASTM D790/ISO 178 | 200 °C |
0.45MPa | ASTM D790/ISO 178 | 216 °C | |
Linear coefficient of thermal expansion | Parallel | ISO 11359-1/-2 | 0.26 E-4/C |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
UL flame retardant rating | 0.75mm | UL 94 | HB |
Compared to the anti leakage trace index | 3.0mm | UL 746A | PLC 1 |
Volume resistivity | IEC 60093 | 1E+13 E-4/C |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.