POM Delrin® 900P DUPONT SHENZHEN
355
- Unit Price:US$ 5,451 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:135MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:wear resistant|High rigidity|high strength|enhance|High impact resistance|High mobility
- Application Areas:Fiber grade|Thin walled products
- Color:--
- Grade:Injection grade
Material Certification

Technical Data Sheet
impact performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 200 kJ/m² |
-30°C | ISO 179/1eU | 200 kJ/m² | |
Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 8.0 kJ/m² |
-30°C | ISO 179/1eA | 7.0 kJ/m² | |
Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 7.0 kJ/m² |
-40°C | ISO 180/1A | 8.0 kJ/m² |
flammability | Test Condition | Test Method | Test Result |
---|---|---|---|
Burning rate | 1.00mm | ISO 3795 | 20 mm/min |
UL flame retardant rating | 0.8mm | UL 94 | HB |
Extreme Oxygen Index | ISO 4589-2 | 23 % | |
FMVSS flammability | FMVSS302 | B | |
Atomization | F-value(refraction) | ISO 6452 | 95 % |
G-value(condensate) | ISO 6452 | 2E-04 g | |
UL flame retardant rating | 1.5mm | UL 94 | HB |
0.8mm | IEC 60695-11-10,-20 | HB | |
1.5mm | IEC 60695-11-10,-20 | HB |
mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Friction coefficient | vs.Itself-Dynamic,1hr | ASTM D1894 | 0.25 |
Bending modulus | ISO 178 | 3000 Mpa | |
Tensile creep modulus | 1000hr | ISO 899-1 | 1500 Mpa |
1hr | ISO 899-1 | 2800 Mpa | |
Nominal tensile fracture strain | ISO 527-2 | 23 % | |
Tensile modulus | ISO 527-2 | 3300 Mpa | |
tensile strength | Yield | ISO 527-2 | 71.0 Mpa |
Tensile strain | Yield | ISO 527-2 | 12 % |
thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Linear coefficient of thermal expansion | MD:23to55°C | ASTME831 | 1E-04 cm/cm/°C |
Melting temperature | ISO 11357-3 | 178 °C | |
Vicat softening temperature | ISO 306/B50 | 160 °C | |
Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 94.0 °C |
0.45MPa,Unannealed | ISO 75-2/B | 162 °C | |
Effective thermal diffusivity coefficient | 8E-08 m²/s | ||
AnnealingTime-Optional | 30.0 min/mm | ||
AnnealingTemperature | 160 °C | ||
Linear coefficient of thermal expansion | TD | ISO 11359-2 | 1.2E-04 cm/cm/°C |
MD | ISO 11359-2 | 1.2E-04 cm/cm/°C |
Physical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ISO 1183 | 1.42 g/cm³ | |
melt mass-flow rate | ISO 1133 | 25 g/10min | |
Melt Volume Flow Rate (MVR) | 190°C/2.16kg | ISO 1133 | 21.0 cm3/10min |
Shrinkage rate | TD | ISO 294-4 | 1.9 % |
MD | ISO 294-4 | 1.9 % | |
Water absorption rate | Saturation,23°C,2.00mm | ISO 62 | 1.4 % |
Equilibrium,23°C,2.00mm,50%RH | ISO 62 | 0.40 % |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Volume resistivity | IEC 60093 | 1E+14 ohms·cm | |
Relative permittivity | 100Hz | IEC 60250 | 3.80 |
1MHz | IEC 60250 | 3.80 | |
Surface resistivity | IEC 60093 | >1.0E+15 ohms | |
Compared to the anti leakage trace index | IEC 60112 | V | |
Hot wire ignition | 0.750mm | UL 746 | sec |
hardness | Test Condition | Test Method | Test Result |
---|---|---|---|
Rockwell hardness | R-Sale | ISO 2039-2 | 120 |
M-Sale | ISO 2039-2 | 92 |
Supplementary Information | Test Condition | Test Method | Test Result |
---|---|---|---|
EmissionofOrganicCompounds | VDA277 | 4.30 µgC/g | |
Emission | VDA275 | <8.00 mg/kg |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.