Impact strength of simply supported beam without notch
23°C
ISO 179/1eU
NoBreak
Impact strength of simply supported beam without notch
-30°C
ISO 179/1eU
NoBreak
flammability
Test Condition
Test Method
Test Result
Burning wire flammability index
IEC 60695-2-12
850 °C
Extreme Oxygen Index
ISO 4589-2
26 %
UL flame retardant rating
1.5mm
UL 94
HB
mechanical properties
Test Condition
Test Method
Test Result
bending strength
23°C
ISO 178
108 Mpa
Tensile modulus
23°C
ISO 527-2/1
2450 Mpa
tensile strength
Yield,23°C
ISO 527-2/50
74.0 Mpa
Tensile strain
Yield,23°C
ISO 527-2/50
6.6 %
Nominal tensile fracture strain
23°C
ISO 527-2/50
>50 %
Bending modulus
23°C
ISO 178
2450 Mpa
thermal performance
Test Condition
Test Method
Test Result
RTI Imp
UL 746
130 °C
RTI Elec
UL 746
150 °C
Linear coefficient of thermal expansion
TD:23to55°C
ISO 11359-2
6.5E-05 cm/cm/°C
Linear coefficient of thermal expansion
MD:23to55°C
ISO 11359-2
6.5E-05 cm/cm/°C
Hot deformation temperature
0.45MPa,Unannealed
ISO 75-2/B
173 °C
RTI Str
UL 746
150 °C
Vicat softening temperature
ISO 306/B120
183 °C
Hot deformation temperature
1.8MPa,Unannealed
ISO 75-2/A
158 °C
Physical properties
Test Condition
Test Method
Test Result
Melt Volume Flow Rate (MVR)
330°C/2.16kg
ISO 1133
18.0 cm3/10min
melt mass-flow rate
330°C/2.16kg
ISO 1133
19 g/10min
density
23°C
ISO 1183
1.15 g/cm³
Shrinkage rate
TD:2.00mm
ISO 294-4
0.85 %
Shrinkage rate
MD:2.00mm
ISO 294-4
0.85 %
Water absorption rate
Saturation,23°C
ISO 62
0.30 %
Water absorption rate
Equilibrium,23°C,50%RH
ISO 62
0.12 %
Electrical performance
Test Condition
Test Method
Test Result
Compared to the anti leakage trace index
SolutionB
IEC 60112
V
Compared to the anti leakage trace index
SolutionA
IEC 60112
V
Dissipation factor
23°C,1MHz
IEC 60250
8E-03
Dissipation factor
23°C,100Hz
IEC 60250
1E-03
Relative permittivity
23°C,1MHz
IEC 60250
2.80
Relative permittivity
23°C,100Hz
IEC 60250
2.90
Dielectric strength
23°C,1.00mm
IEC 60243-1
35 KV/mm
Volume resistivity
23°C
IEC 60093
1E+17 ohms·cm
Surface resistivity
IEC 60093
1E+16 ohms
hardness
Test Condition
Test Method
Test Result
Ball Pressure Test
ISO 2039-1
127 Mpa
Supplementary Information
Test Condition
Test Method
Test Result
Electrolytic corrosion
23°C
IEC 60426
A1
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.