PBT CELANEX®  2002 CELANESE USA

389
  • Unit Price:US$ 3,250 /MT
  • Packaging Specification:
    25 KG/PKG
  • Packaging Material:
    Paper bag
  • Supply Quantity:
    33MT
  • Delivery Terms:
    FOB
  • Port of Loading :
    Guangzhou port, China
  • Accepted Payment Methods:
    T/T
  • Shipping:
    Negotiate supplier for shipping details

Supplier Information

ASIA PLASTIC EXCHANGE LIMITED

+86 755 ********View
serv********View
+86 ********View

For more details, please contact the supplier!

Material Description

  • Material Properties:Flame retardantGood flexibilityGlass fiber reinforced
  • Application Areas:Electrical fieldElectronic field
  • Color:--
  • Grade:Injection grade

Technical Data Sheet

mechanical propertiesTest ConditionTest MethodTest ResultTest Unit
Impact strength of simply supported beam without notch-30℃ISO 179/1eU190KJ/m
Impact strength of simply supported beam without notch23℃ISO 179/1eUNBKJ/m
bending strength23℃ISO 17880Mpa
Bending modulus23℃ISO 1782500Mpa
tensile strengthISO 527-2/1A60Mpa
Rockwell hardnessISO 2039-278M
Impact strength of cantilever beam gap23℃ISO 180/1A5.0KJ/m
Charpy Notched Impact Strength-30℃ISO 179/1eA6KJ/m
Charpy Notched Impact Strength23℃ISO 179/1eA6KJ/m
Tensile modulus50mm/min,YieldISO 527-2/1A4%
Tensile stress50mm/min,YieldISO 527-2/1A60Mpa
Tensile modulus1mm/minISO 527-2/1A2600Mpa
thermal performanceTest ConditionTest MethodTest ResultTest Unit
Hot deformation temperature1.8MpaISO 75-1/-255°C
Hot deformation temperature0.45MpaISO 75-1/-2150°C
Vicat softening temperatureISO 306190°C
Glass transition temperatureISO 11357-160°C
Melting temperatureISO 11357-1225°C
Linear coefficient of thermal expansionAcross FlowISO 11359-21.1E-4/℃
Linear coefficient of thermal expansionAcross FlowISO 11359-21.27E-4/℃
UL flame retardant ratingUL 94HB
Physical propertiesTest ConditionTest MethodTest ResultTest Unit
Water absorption rate23℃,SaturationISO 620.09%
Extreme Oxygen IndexISO 458922%
densityISO 11831310kg/m
Melt Volume Flow Rate (MVR)ISO 113320CM
Shrinkage rateISO 294-41.8-2.0%
Electrical performanceTest ConditionTest MethodTest ResultTest Unit
Compared to the Leakage Traceability Index (CTI)IEC 60112600
Dielectric strengthIEC 60243-123KV/mm
Surface resistivityIEC 600931E+15Ohm
Volume resistivityIEC 600931E+13ohm.m
Dielectric dissipation factor1MHzIEC 60250220E-4
Dielectric dissipation factor100HzIEC 6025014E-4
Volume resistivity1MHzIEC 602503.5
Volume resistivity100HzIEC 602504
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.