MVLDPE DOWLEX™ 2045.11G STYRON US
272
- Unit Price:US$ 1,342 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:12MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
+86 ********View
For more details, please contact the supplier!
Material Description
- Material Properties:--
- Application Areas:--
- Color:--
- Grade:Injection grade
Technical Data Sheet
optical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
gloss | 45° | ASTM D2457 | 34 |
turbidity | ASTM D1003 | 20 % | |
gloss | 45°,20.3um | ASTM D-2457 | 70 |
45°,50.8um | ASTM D-2457 | 67 | |
turbidity | 20.3um | ASTM D-1003 | 7 % |
50.8um | ASTM D-1003 | 10 % |
Other performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Film toughness | 20.3um,TD | ASTM D-882 | 304 J/cm³ |
20.3um,MD | ASTM D-882 | 240 J/cm4 | |
50.8um,MD | ASTM D-882 | 273 J/cm5 | |
50.8um,TD | ASTM D-882 | 292 J/cm6 | |
Thin film puncture strength | 20.3um | Internal Method | 11.4 J/cm³ |
50.8um | Internal Method | 9.76 J/cm³ |
machinability | Test Condition | Test Method | Test Result |
---|---|---|---|
Melt Temperature | 221-232 °C |
Basic Performance | Test Condition | Test Method | Test Result |
---|---|---|---|
melt mass-flow rate | 190℃/2.16kg | ASTM D-1238 | 1 g/10min |
density | ASTM D-792 | 0.922 g/m3 |
mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
Elmendorf tear strength | 50.8um,MD | ASTM D-1922 | 740 g |
50.8um,TD | ASTM D-1922 | 1200 g | |
20.3um,MD | ASTM D-1922 | 440 g | |
Elongation at Break | 50.8um,TD | ASTM D-882 | 770 % |
20.3um,TD | ASTM D-882 | 750 % | |
20.3um,MD | ASTM D-882 | 480 % | |
tensile strength | 50.8um,TD,Break | ASTM D-882 | 44.3 Mpa |
50.8um,MD,Break | ASTM D-882 | 51.9 Mpa | |
20.3um,TD,Break | ASTM D-882 | 49.2 Mpa | |
20.3um,MD,Break | ASTM D-882 | 60.4 Mpa | |
50.8um,Yield,TD | ASTM D-882 | 12.6 Mpa | |
50.8um,Yield,MD | ASTM D-882 | 11.8 Mpa | |
20.3um,Yield,MD | ASTM D-882 | 12.7 Mpa | |
20.3um,Yield,TD | ASTM D-882 | 13.1 Mpa | |
Secant modulus | 2% Secant,50.8um,TD | ASTM D-882 | 234 Mpa |
2% Secant,50.8um,MD | ASTM D-882 | 196 Mpa | |
20.3um,TD | ASTM D-882 | 247 Mpa | |
20.3um,MD | ASTM D-882 | 227 Mpa | |
Elmendorf tear strength | 20.3um,TD | ASTM D-1922 | 580 g |
Dart impact | 50.8um | ASTM D-1709A | 280 g |
20.3um | ASTM D-1709A | 130 g | |
Elongation at Break | 50.8um,MD | ASTM D-882 | 670 % |
thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Vicat softening temperature | ASTM D-1525 | 104 °C | |
Melting temperature | Internal Method | 122 °C | |
Internal Method | 122 °C | ||
Vicat softening temperature | ASTM D1525 | 104 °C |
Physical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
melt mass-flow rate | 190°C/2.16kg | ASTM D1238 | 1.0 g/10min |
film | Test Condition | Test Method | Test Result |
---|---|---|---|
tensile strength | MD:Break | ASTM D882 | 46.1 Mpa |
TD:Break | ASTM D882 | 35.3 Mpa | |
elongation | MD:Break | ASTM D882 | 540 % |
TD:Break | ASTM D882 | 660 % | |
Secant modulus | 1%Secant,TD | ASTM D882 | 234 Mpa |
2%Secant,TD | ASTM D882 | 189 Mpa | |
tensile strength | MD:Yield | ASTM D882 | 13.4 Mpa |
TD:Yield | ASTM D882 | 14.1 Mpa | |
film thickness | Internal Method | 25 µm | |
Thin film puncture strength | Internal Method | 1.24 J | |
Internal Method | 31.1 N | ||
Internal Method | 6.21 J/cm³ | ||
Membrane strength | MD | ASTM D882 | 110 J/cm³ |
TD | ASTM D882 | 114 J/cm³ | |
Secant modulus | 1%Secant,MD | ASTM D882 | 211 Mpa |
2%Secant,MD | ASTM D882 | 172 Mpa | |
Dart impact | ASTM D1709A | 180 g | |
Elmendorf tear strength | MD | ASTM D1922 | 440 g |
TD | ASTM D1922 | 630 g |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.