PA6 Amilan® CM1011G-30 BK TORAY JAPAN
245
- Unit Price:US$ 2,258 /MT
- Packaging Specification:25 KG/PKG
- Packaging Material:Paper bag
- Supply Quantity:189MT
- Delivery Terms:FOB
- Port of Loading :China Main Port
- Accepted Payment Methods:T/T
- Shipping:Negotiate supplier for shipping details
Supplier Information
ASIA PLASTIC EXCHANGE LIMITED
+86 755 ********View
serv********View
For more details, please contact the supplier!
Material Description
- Material Properties: Glass 45% reinforced|High modulus application|High impact| Glass 45% reinforced|High modulus application|High impact
- Application Areas:Shell|Automotive sector
- Color:--
- Grade:--
Technical Data Sheet
physical property | Test Condition | Test Method | Test Result |
---|---|---|---|
density | ASTM D-792 | 无水|1.5 | |
ASTM D-792 | 1.9%水|- | ||
Taber abraser | ASTM D-1044 | 无水|30 mg/1000次 | |
ASTM D-1044 | 1.9%水|- mg/1000次 |
Basic performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Water absorption rate | ASTM D-570 | 无水|0.9 % | |
ASTM D-570 | 1.9%水|- % |
Mechanical properties | Test Condition | Test Method | Test Result |
---|---|---|---|
tensile strength | ASTM D-638 | 无水|2900 kg/cm2 | |
ASTM D-638 | 1.9%水|- kg/cm2 | ||
compressive strength | ASTM D-695 | 无水|1900 kg/cm2 | |
ASTM D-695 | 1.9%水|- kg/cm2 | ||
ASTM D-695 | 无水|1000 kg/cm2 | ||
ASTM D-695 | 1.9%水|- kg/cm2 | ||
ASTM D-695 | 无水|2600 kg/cm2 | ||
ASTM D-695 | 1.9%水|- kg/cm2 | ||
Impact strength of cantilever beam gap | ASTM D-256 | 1.9%水|120 kg·cm/cm | |
Flexural modulus | ASTM D-790 | 无水|122000 kg/cm2 | |
ASTM D-790 | 1.9%水|72000 kg/cm2 | ||
ASTM D-790 | 无水|63000 kg/cm2 | ||
ASTM D-790 | 1.9%水|45000 kg/cm2 | ||
ASTM D-790 | 无水|140000 kg/cm2 | ||
ASTM D-790 | 1.9%水|120000 kg/cm2 | ||
Rockwell hardness | ASTM D-785 | 无水|95 M-标度 | |
ASTM D-785 | 1.9%水|- M-标度 | ||
ASTM D-785 | 无水|121 R-标度 | ||
elongation at break | ASTM D-638 | 无水|5 % | |
ASTM D-638 | 1.9%水|5 % | ||
Impact strength of cantilever beam gap | ASTM D-256 | 无水|12.5 kg·cm/cm | |
ASTM D-256 | 1.9%水|15 kg·cm/cm | ||
ASTM D-256 | 无水|12.5 kg·cm/cm2 | ||
ASTM D-256 | 1.9%水|15 kg·cm/cm2 | ||
ASTM D-256 | 无水|15 kg·cm/cm | ||
ASTM D-256 | 1.9%水|20 kg·cm/cm | ||
ASTM D-256 | 无水|98 kg·cm/cm | ||
shearing strength | ASTM D-732 | 无水|940 kg/cm2 | |
ASTM D-732 | 1.9%水|750 kg/cm2 | ||
Rockwell hardness | ASTM D-785 | 1.9%水|- R-标度 | |
bending strength | ASTM D-790 | 无水|2900 kg/cm2 | |
ASTM D-790 | 1.9%水|1850 kg/cm2 | ||
ASTM D-790 | 无水|16000 kg/cm2 | ||
ASTM D-790 | 1.9%水|- kg/cm2 | ||
ASTM D-790 | 无水|3300 kg/cm2 | ||
ASTM D-790 | 1.9%水|- kg/cm2 | ||
tensile strength | ASTM D-638 | 无水|2000 kg/cm2 | |
ASTM D-638 | 1.9%水|1300 kg/cm2 | ||
ASTM D-638 | 无水|1200 kg/cm2 | ||
ASTM D-638 | 1.9%水|- kg/cm2 |
Other performance | Test Condition | Test Method | Test Result |
---|---|---|---|
filler content | 无水|45 wt% | ||
1.9%水|- wt% |
Electrical performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Volume resistivity | ASTM D-257 | 1.9%水|1012 Ω.cm | |
Dissipation Factor | ASTM D-150 | 无水|0.03 | |
ASTM D-150 | 1.9%水|0.16 | ||
arc resistance | ASTM D-495 | 无水|104 S | |
ASTM D-495 | 1.9%水|119 S | ||
Volume resistivity | ASTM D-257 | 无水|1015 Ω.cm | |
dielectric constant | ASTM D-150 | 1.9%水|7.4 | |
ASTM D-150 | 无水|4.9 | ||
ASTM D-150 | 无水|4.2 | ||
ASTM D-150 | 1.9%水|4.5 | ||
dielectric strength | ASTM D-149 | 1.9%水|15 KV/mm | |
ASTM D-149 | 无水|19 KV/mm | ||
Dissipation Factor | ASTM D-150 | 无水|0.02 | |
ASTM D-150 | 1.9%水|0.06 |
Thermal performance | Test Condition | Test Method | Test Result |
---|---|---|---|
Linear coefficient of thermal expansion | ASTM D-696 | 1.9%水|- ×10-5cm/cm/℃ | |
ASTM D-696 | 无水|2-3 ×10-5cm/cm/℃ | ||
specific heat | 1.9%水|- Cal/g·℃ | ||
无水|0.31 Cal/g·℃ | |||
melting temperature | 差示扫描测热计DSC | 225 °C | |
Heat distortion temperature | ASTM D-648 | 1.9%水|- °C | |
ASTM D-648 | 无水|225 °C | ||
UL-94 flame retardant grade | UL 94 | 无水|HB | |
UL 94 | 1.9%水|- |
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.