PA12 VESTAMID® L-GF30 EVONIK GERMANY

565
  • Unit Price:US$ 8,874 /MT
  • Packaging Specification:
    25 KG/PKG
  • Packaging Material:
    Paper bag
  • Supply Quantity:
    27MT
  • Delivery Terms:
    FOB
  • Port of Loading :
    China Main Port
  • Accepted Payment Methods:
    T/T
  • Shipping:
    Negotiate supplier for shipping details

Supplier Information

ASIA PLASTIC EXCHANGE LIMITED

+86 755 ********View
serv********View
+86 ********View

For more details, please contact the supplier!

Material Description

  • Material Properties:low densityHigh elasticityPhotostabilityLow temperature impact resistanceLow friction coefficientResistance to stress crackingFatigue resistance
  • Application Areas:bearing
  • Color:--
  • Grade:Injection grade

Material Certification

UL

Technical Data Sheet

mechanical propertiesTest ConditionTest MethodTest Result
Charpy Notched Impact Strength-30℃ISO 179/1eA21 C KJ/m
Charpy Notched Impact Strength23℃ISO 179/1eA23 C KJ/m
Charpy Notched Impact Strength-30℃ISO 179/1eU100 C KJ/m
Charpy Notched Impact Strength23℃ISO 179/1eU100 C KJ/m
Tensile modulusISO 527-1/-26500 Mpa
Fracture stressISO 527-1/-2120 Mpa
Fracture strainISO 527-1/-25 %
thermal performanceTest ConditionTest MethodTest Result
Hot deformation temperature0.45MpaISO 75175
Hot deformation temperature1.8MpaISO 75165
Melting temperatureISO 3146178
Vicat softening temperatureISO 306175
Linear coefficient of thermal expansionISO 113590.6
UL flame retardant ratingUL 94HB
Physical propertiesTest ConditionTest MethodTest Result
densityISO 11831.24
Shrinkage rateAcross FlowISO 294-40.65 %
Shrinkage rateAcross FlowISO 294-40.15 %
Water absorption rate23℃,50%相对湿度ISO 620.5 %
Water absorption rate23℃,SaturationISO 621.1 %
Electrical performanceTest ConditionTest MethodTest Result
Dielectric loss1MHz,TangentIEC 60250330 10
Dielectric loss100Hz,TangentIEC 60250310 10
Dielectric strengthIEC 60243-144 KV/mm
Volume resistivityIEC 6009310 Ω.cm
Dielectric constant1MHzIEC 602503.4
Dielectric constant100HzIEC 602504.1
Relative discharge indexIEC 60112>600
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.