PBT LNP™ LUBRICOMP™  WL004 GY03565 SABIC INNOVATIVE US

190
  • Unit Price:US$ 4,025 /MT
  • Packaging Specification:
    25 KG/PKG
  • Packaging Material:
    Paper bag
  • Supply Quantity:
    50MT
  • Delivery Terms:
    FOB
  • Port of Loading :
    China Main Port
  • Accepted Payment Methods:
    T/T
  • Shipping:
    Negotiate supplier for shipping details

Supplier Information

ASIA PLASTIC EXCHANGE LIMITED

+86 755 ********View
serv********View

For more details, please contact the supplier!

Material Description

  • Material Properties:High rigidityhigh strength
  • Application Areas:Home appliance componentsAutomotive Applications
  • Color:--
  • Grade:--

Technical Data Sheet Compare

thermal performanceTest ConditionTest MethodTest Result
Linear coefficient of thermal expansionMD:-40到40°CISO 11359-29E-05 cm/cm/°C
Linear coefficient of thermal expansionTD:-40到40°CASTME8319.6E-05 cm/cm/°C
Linear coefficient of thermal expansionTD:-40到40°CISO 11359-29.6E-05 cm/cm/°C
Heat Deflection Temperature1.8MPa,未退火,3.20mmASTM D64855.0 °C
Heat Deflection Temperature1.8MPa,未退火,64.0mm跨距ISO 75-2/Af61.0 °C
Linear coefficient of thermal expansionMD:-40到40°CASTME8319E-05 cm/cm/°C
Physical propertiesTest ConditionTest MethodTest Result
shrinkage rateMD:24小时ASTM D9552.1-2.4 %
shrinkage rateTD:24hrASTM D9552.1-2.4 %
shrinkage rateTD:24小时ISO 294-42.1-2.3 %
shrinkage rateMD:24小时ISO 294-42.4-2.5 %
water absorption rate24hr,50%RHASTM D5700.051 %
water absorption rate平衡,23°C,50%RHISO 620.080 %
mechanical propertiesTest ConditionTest MethodTest Result
tensile strength断裂ASTM D63849.0 Mpa
tensile strength断裂ISO 527-245.0 Mpa
elongation断裂ASTM D6389.8 %
Tensile strain断裂ISO 527-28.4 %
flexural modulusASTM D7902410 Mpa
flexural modulusISO 1782390 Mpa
bending strengthASTM D79078.7 Mpa
bending strengthISO 17877.1 Mpa
coefficient of frictionDynamicASTM D3702Modified0.33
coefficient of frictionStaticASTM D3702Modified0.24
tensile modulusASTM D6382410 Mpa
tensile modulusISO 527-2/12450 Mpa
Wear factorWasherASTM D3702Modified58.0 10^-10in^5-min/ft-lb-hr
impact performanceTest ConditionTest MethodTest Result
Impact strength of cantilever beam gap23°CISO 180/1A3.6 kJ/m²
Suspended wall beam without notch impact strength23°CISO 180/1U30 kJ/m²
Dart impact23°C,EnergyatPeakLoadASTM D37630.960 J
Multi axis Instrumented Impact EnergyISO 6603-20.500 J
IMPORTANT NOTES: Plas.com collected the data in the data sheet from the material manufacturers. Plas.com makes the best effort to improve the accuracy of the data, but has no responsibility for the data. We strongly recommend verifying the validity of the data with the material manufacturers before making a final decision.

Contact Us

Get App

Top